Flammability, Smoke and Dry Arc Tracking Tests of Aircraft Electrical Wire Insulations
-
1989-07-01
Details
-
Creators:
-
Corporate Creators:
-
Subject/TRT Terms:
-
Publication/ Report Number:
-
Resource Type:
-
Geographical Coverage:
-
Edition:Final Report
-
Corporate Publisher:
-
Abstract:Although three different laboratory-scale tests WE:H: evaluated in this wire program, only the sixty-degree test is currently required by the Federal Aviation Administration (FAA). All test specimens with the exception of MIL-W-5086/1-PVC nylon passed this test with average burn lengths within the 3-inch maximum and no flame time. The MIL-W-5086/1 samples marginally passed the 30-second flame time, and the average burn length was greater than the 3-inch maximum specified in the FAR.
-
Format:
-
Collection(s):
-
Main Document Checksum:urn:sha-512:31ad2243188f72d010d892a1000516a26980cf346914d9988bf5ddc7b0a2ce03a7a187526e3e642ea4d0a22f28d9a0e0d5b77017a7fbafab48fa071eedcec0ed
-
Download URL:
-
File Type: