An Investigation of the FAA Vertical Bunsen Burner Flammability Test Method
-
1986-08-01
Details
-
Creators:
-
Corporate Creators:
-
Subject/TRT Terms:
-
Publication/ Report Number:
-
Resource Type:
-
Geographical Coverage:
-
Edition:Final Report
-
Corporate Publisher:
-
Abstract:The vertical Bunsen burner test method, as specified in appendix F of the Federal Aviation Regulations-Part 25, was evaluated in order to update and clarify certain problem areas. Burner fuel, flame temperature and flame placement were investigated. It was determined that 1 methane gas can be used as a replacement or alternative to B-gas, 2 a minimum flame temperature specification is meaningless without specifying thermocouple wire thickness, and 3 placing the flame at the midpoint of the lower edge of the front face results in a more realistic and severe evaluation of the specimens flammability properties.
-
Format:
-
Collection(s):
-
Main Document Checksum:urn:sha-512:d733f4ce01ffd1433278ec2c179a770d938c4e55bb000e5d9e305527471e72ada49232282eff8f359054cccdb10ab7cb18898c8ae7e4f12d2b7ffec3c9f8f6c4
-
Download URL:
-
File Type: