A Laboratory Test for Evaluating the Fire Containment Characteristics of Aircraft Class D Cargo Compartment Lining Material
-
1983-10-01
Details
-
Creators:
-
Corporate Creators:
-
Subject/TRT Terms:
-
Publication/ Report Number:
-
Resource Type:
-
Geographical Coverage:
-
Edition:Final Report
-
Corporate Publisher:
-
Abstract:The Federal Aviation Administration Standard 2-gallon/hour burner was adapted to measure the burn-through resistance of aircraft cargo compartment lining materials. This laboratory test can subject lining samples to the fire conditions found in full-scale class D cargo compartment tests. A 5-minute test period is of adequate duration to evaluate the performance of cargo lining materials, based on full-scale test results which showed that class D fire intensity is reduced to a smoldering state after several minutes. It was determined that the 2-gallon/hour burner test is superior to the vertical and 45° Bunsen burner tests specified in Federal Air Regulations (FAK's) 25.853 and 25.855 for evaluating the flammability and burn-through resistance of cargo compartment lining materials. The following criteria for class D cargo compartment lining materials using the 2-gallon/hour burner test are proposed: Sample must prevent burn-through for 5 minutes, and peak temperatures at 4 inches above the upper surface of a horizontal test sample should not exceed 400° Fahrenheit. Based on the results of this laboratory test, it is concluded that fiberglass lining materials provide sufficient protection to prevent burn-through in a class D cargo compartment fire, however, Nomex and Kevlar lining materials will not contain a class D cargo compartment fire.
-
Format:
-
Funding:
-
Collection(s):
-
Main Document Checksum:urn:sha-512:df13a2ce78bf9256c126ccedfa2a0497389311cc036ac852f4252e22c5e17eb389ea93e8b89cc8ca590451676bebe8d256a38c4a6de07773c8fc66598d18ce7d
-
Download URL:
-
File Type: