Improvement of Device (CMD) for Monitoring the Consolidation of Plastic Concrete
-
1981-08-01
Details:
-
Creators:
-
Corporate Creators:
-
Contributors:
-
Corporate Contributors:
-
Subject/TRT Terms:
-
Publication/ Report Number:
-
Resource Type:
-
Geographical Coverage:
-
Edition:Final Report
-
Contracting Officer:
-
Corporate Publisher:
-
Abstract:This report describes a program to develop an automatic distance gauging system for use in a device (CMD) for monitoring the consolidation of a portland cement concrete pavement. The capacitive distance gauging system measures the air gap between the surface of the pavement and the bottom of a gamma backscatter instrument for density monitoring. The incorporation of the capacitance gauging system has successfully made the density measurement independent of air gap height variations normally encountered as the concrete pavement surface is extruded behind a paving machine. Laboratory and field testing programs are described, and recommendations are made for further development and application of the density monitoring system.
-
Format:
-
Funding:
-
Collection(s):
-
Main Document Checksum:
-
Download URL:
-
File Type: