Reda Taha, M. M., Halter, S. B., Abdellatef, M., & Murcia, D. H. (2022). Field Retrofit and Testing of a Corroded Metal Culvert Using GFRP (Report No. 20STUNM30). Transportation Consortium of South-Central States. https://rosap.ntl.bts.gov/view/dot/62298
Reda Taha, M. M., Susan Bogus Halter, Mohammed Abdellatef, and Daniel Heras Murcia. Field Retrofit and Testing of a Corroded Metal Culvert Using GFRP. Report no. 20STUNM30. Transportation Consortium of South-Central States, 2022. https://rosap.ntl.bts.gov/view/dot/62298.
Reda Taha, M. M., et al. Field Retrofit and Testing of a Corroded Metal Culvert Using GFRP. Transportation Consortium of South-Central States, 2022, Report no. 20STUNM30, ROSA P. https://rosap.ntl.bts.gov/view/dot/62298.
One of the current pressing problem for all DOTs is the corrosion-oriented deterioration of the existing metal culverts. These metal culverts typically are designed for a life of 50 years. However, corrosion is making them last no longer than 30years. Here we propose use of Glass Fiber Reinforced Polymers (GFRP) pipe section as a fit-in GFRP profile liner for complete repair and rehabilitation of the corroded metal culvert with an expected life of 75 years. This is mainly because of the corrosion free nature of the GFRP material. In the current study, the design method for using glass fiber-reinforced polymer (GFRP) slip liner to retrofit CMP culvert is presented. Furthermore, this report presents field implementation of retrofitting of a 24 in corroded corrugated metal pipe embedded that is 25 ft span and buried below 18 of soil. The corroded corrugated metal pipe was retrofitted with a 22 in diameter GFRP slip liner. Load testing before and after the retrofitting proves the efficiency of the proposed retrofitting system and its ability to extend the service life of the retrofitted pipe.
One of the current pressing problem for all DOTs is the corrosion-oriented deterioration of the existing metal culverts. These metal culverts typicall
...
Reda Taha, M. M., Halter, S. B., Abdellatef, M., & Murcia, D. H. (2022). Field Retrofit and Testing of a Corroded Metal Culvert Using GFRP (Report No. 20STUNM30). Transportation Consortium of South-Central States. https://rosap.ntl.bts.gov/view/dot/62298
Reda Taha, M. M., Susan Bogus Halter, Mohammed Abdellatef, and Daniel Heras Murcia. Field Retrofit and Testing of a Corroded Metal Culvert Using GFRP. Report no. 20STUNM30. Transportation Consortium of South-Central States, 2022. https://rosap.ntl.bts.gov/view/dot/62298.
Reda Taha, M. M., et al. Field Retrofit and Testing of a Corroded Metal Culvert Using GFRP. Transportation Consortium of South-Central States, 2022, Report no. 20STUNM30, ROSA P. https://rosap.ntl.bts.gov/view/dot/62298.
ROSA P serves as an archival repository of USDOT-published products including scientific
findings, journal articles, guidelines, recommendations, or other information authored or co-authored by
USDOT or funded partners. As a repository, ROSA P retains documents in their original published format to
ensure public access to scientific information.
Links with this icon indicate that you are leaving a Bureau of Transportation
Statistics (BTS)/National Transportation Library (NTL)
Web-based service.
Thank you for visiting.
You are about to access a non-government link outside of
the U.S. Department of Transportation's National
Transportation Library.
Please note: While links to Web sites outside of DOT are
offered for your convenience, when you exit DOT Web sites,
Federal privacy policy and Section 508 of the Rehabilitation
Act (accessibility requirements) no longer apply. In
addition, DOT does not attest to the accuracy, relevance,
timeliness or completeness of information provided by linked
sites. Linking to a Web site does not constitute an
endorsement by DOT of the sponsors of the site or the
products presented on the site. For more information, please
view DOT's Web site linking policy.
To get back to the page you were previously viewing, click
your Cancel button.