Quintiere, J. G. (1982). An Assessment of Correlations Between Laboratory and Full-Scale Experiments for the FAA Aircraft Fire Safety Program, Part 4: Flammability Tests (Report No. NBSIR 82-2525). United States. Department of Transportation. Federal Aviation Administration. William J. Hughes Technical Center. https://rosap.ntl.bts.gov/view/dot/92204
Quintiere, James G.. An Assessment of Correlations Between Laboratory and Full-Scale Experiments for the FAA Aircraft Fire Safety Program, Part 4: Flammability Tests. Report no. NBSIR 82-2525. United States. Department of Transportation. Federal Aviation Administration. William J. Hughes Technical Center, 1982. https://rosap.ntl.bts.gov/view/dot/92204.
Quintiere, James G. An Assessment of Correlations Between Laboratory and Full-Scale Experiments for the FAA Aircraft Fire Safety Program, Part 4: Flammability Tests. United States. Department of Transportation. Federal Aviation Administration. William J. Hughes Technical Center, 1982, Report no. NBSIR 82-2525, ROSA P. https://rosap.ntl.bts.gov/view/dot/92204.
A review is made of studies in which full-scale fire growth was compared with laboratory test data on materials. Both room and corridor fires are included in which primarily interior lining materials have been the combustible element. The studies include standard test methods and other laboratory devices used in the United States and other countries. An effort was made to intercompare experimental results in a common basis. For example, maximum room temperature data are compared with ASTM E-84 flame spread classifications for several full-scale tests which involved nearly the same room geometries and same fuel arrangements.
An attempt is made to develop mathematical predictions for various aspects of the dynamics of post crash aircraft fires. The basis of the analysis is
...
Quintiere, J. G. (1982). An Assessment of Correlations Between Laboratory and Full-Scale Experiments for the FAA Aircraft Fire Safety Program, Part 4: Flammability Tests (Report No. NBSIR 82-2525). United States. Department of Transportation. Federal Aviation Administration. William J. Hughes Technical Center. https://rosap.ntl.bts.gov/view/dot/92204
Quintiere, James G.. An Assessment of Correlations Between Laboratory and Full-Scale Experiments for the FAA Aircraft Fire Safety Program, Part 4: Flammability Tests. Report no. NBSIR 82-2525. United States. Department of Transportation. Federal Aviation Administration. William J. Hughes Technical Center, 1982. https://rosap.ntl.bts.gov/view/dot/92204.
Quintiere, James G. An Assessment of Correlations Between Laboratory and Full-Scale Experiments for the FAA Aircraft Fire Safety Program, Part 4: Flammability Tests. United States. Department of Transportation. Federal Aviation Administration. William J. Hughes Technical Center, 1982, Report no. NBSIR 82-2525, ROSA P. https://rosap.ntl.bts.gov/view/dot/92204.
ROSA P serves as an archival repository of USDOT-published products including scientific
findings, journal articles, guidelines, recommendations, or other information authored or co-authored by
USDOT or funded partners. As a repository, ROSA P retains documents in their original published format to
ensure public access to scientific information.
Links with this icon indicate that you are leaving a Bureau of Transportation
Statistics (BTS)/National Transportation Library (NTL)
Web-based service.
Thank you for visiting.
You are about to access a non-government link outside of
the U.S. Department of Transportation's National
Transportation Library.
Please note: While links to Web sites outside of DOT are
offered for your convenience, when you exit DOT Web sites,
Federal privacy policy and Section 508 of the Rehabilitation
Act (accessibility requirements) no longer apply. In
addition, DOT does not attest to the accuracy, relevance,
timeliness or completeness of information provided by linked
sites. Linking to a Web site does not constitute an
endorsement by DOT of the sponsors of the site or the
products presented on the site. For more information, please
view DOT's Web site linking policy.
To get back to the page you were previously viewing, click
your Cancel button.