Conducted Electrical Emissions From Type L-858 Style 2 and 3 Airfield Signs
-
2008-11-01
Details
-
Creators:
-
Corporate Creators:
-
Corporate Contributors:
-
Subject/TRT Terms:
-
Publication/ Report Number:
-
Resource Type:
-
Geographical Coverage:
-
Edition:Technical Note
-
Corporate Publisher:
-
Abstract:This study investigated the conducted electrical emissions from Type L-858 style 2 and 3 airfield signs that cause the signs to flicker on and off. These emissions are caused by the internal power supply of the style 2 and 3 signs. These signs are designed to operate at a constant intensity on a series circuit with other lighting equipment that operates with either a three- or five-step intensity constant current regulator. The test setup consisted of an airfield sign power supply and three subsystems: (1) a circuit current control that provided constant current to the power supply, (2) a line impedance stabilization network that provided a 60-hertz sign wave to the sign power supply, and (3) a data acquisition system. For style 2 and 3 signs that include internal power supplies, the level of emissions should not exceed -6 decibel milliamperes (dBmA) for proper operation. Circuits that include style 2 or 3 signs should be run in separate conduits to prevent operational problems if the emissions exceed -6 dBmA. The practice of double-circuiting should be used when the circuits outbound and return cables are in the same conduit with no single-conductor runs. This will reduce the potential for crosstalk. The use of line filters should be considered for these signs if no other means is practical.
-
Format:
-
Collection(s):
-
Main Document Checksum:urn:sha-512:fe2e1792cdce4c7e96d51575d7acfed7b991aded765b23cd84900b83727628f3b1a2805829ad872e878e1502aae338570931b354c1f9d0936a9697f0a7dce52c
-
Download URL:
-
File Type: