An Evaluation of the Flammability of Aircraft Wiring
-
2004-12-01
Details
-
Creators:
-
Corporate Creators:
-
Corporate Contributors:
-
Subject/TRT Terms:
-
Publication/ Report Number:
-
Resource Type:
-
Geographical Coverage:
-
Edition:Technical Note
-
Corporate Publisher:
-
Abstract:This report discusses the flammability tests conducted on aviation and nonaviation electrical wiring that were performed to re-evaluate the effectiveness of the current Federal Aviation Administration (FAA)-mandated 60° Bunsen burner flammability test requirement for aircraft wiring. The evaluation included a 60° flammability test, an intermediate-scale vertical flammability test, and an intermediate-scale cabin attic flammability test. Test results showed that the 60° single wire Bunsen burner flammability test may not be adequate to qualify wire when bundled and subjected to a severe ignition source.
-
Format:
-
Collection(s):
-
Main Document Checksum:urn:sha-512:693dca5e383c3057b8d992980ed13f84c4a59ddb423cac6d9c611470b5f0620c2b25e4fe0b753b9e59013ead649dff60417704cd9010cb7254b6b2a31a6a60a9
-
Download URL:
-
File Type: