Limiting Oxygen Concentration Required to Inert Jet Fuel Vapors Existing at Reduced Fuel Tank Pressures
-
2003-08-01
Details
-
Creators:
-
Corporate Creators:
-
Corporate Contributors:
-
Subject/TRT Terms:
-
Publication/ Report Number:
-
Resource Type:
-
Geographical Coverage:
-
Edition:Technical Note
-
Corporate Publisher:
-
Abstract:This report discusses experiments to determine the reduction in oxygen concentration required to prevent a fuel tank explosion. A simulated aircraft fuel tank containing JP-8 fuel of an amount equivalent to a mass loading of approximately 4.5 kg/m3 was used to determine the limiting oxygen concentration (LOC) at pressures corresponding to altitudes ranging from 0 to 38 kft. In addition, the peak pressure rise was measured at various altitudes (pressures) due to ignition occurring at O2 levels approximately 1% to 1.5% above the LOC.
-