Rocha, S., Nazarian, S., & Tandon, V. (2003). A Comprehensive Calibration Strategy for Texas Department of Transportation Falling Weight Deflectometer Fleet (Report No. TX-01 1784-2). University of Texas at El Paso. Center for Highway Materials Research. https://rosap.ntl.bts.gov/view/dot/85994
Rocha, S., S. Nazarian, and Vivek Tandon. A Comprehensive Calibration Strategy for Texas Department of Transportation Falling Weight Deflectometer Fleet. Report no. TX-01 1784-2. University of Texas at El Paso. Center for Highway Materials Research, 2003. https://rosap.ntl.bts.gov/view/dot/85994.
Rocha, S., et al. A Comprehensive Calibration Strategy for Texas Department of Transportation Falling Weight Deflectometer Fleet. University of Texas at El Paso. Center for Highway Materials Research, 2003, Report no. TX-01 1784-2, ROSA P. https://rosap.ntl.bts.gov/view/dot/85994.
The degree of accuracy with which the Falling Weight Deflectometer (FWD) data are collected and analyzed has a direct impact on the conclusions drawn in many aspects of TxDOT operation. Since TxDOT owns 15 FWD units, one of the largest FWD fleets of any single transportation agency in the world, high levels of repeatability and reproducibility are considered to be of major importance for an adequate interchangeability of the FWD fleet. As summarized in Research Report 1784-1, the existing calibration protocol improves the repeatability of each FWD but it does not address the reproducibility of the fleet. In this report a new calibration process has been recommended that seems to improve the reproducibility of the fleet. The calibration process consists of three steps: a routine and diagnostic maintenance, a simple calibration procedure followed by a comprehensive one if necessary.
Rocha, S., Nazarian, S., & Tandon, V. (2003). A Comprehensive Calibration Strategy for Texas Department of Transportation Falling Weight Deflectometer Fleet (Report No. TX-01 1784-2). University of Texas at El Paso. Center for Highway Materials Research. https://rosap.ntl.bts.gov/view/dot/85994
Rocha, S., S. Nazarian, and Vivek Tandon. A Comprehensive Calibration Strategy for Texas Department of Transportation Falling Weight Deflectometer Fleet. Report no. TX-01 1784-2. University of Texas at El Paso. Center for Highway Materials Research, 2003. https://rosap.ntl.bts.gov/view/dot/85994.
Rocha, S., et al. A Comprehensive Calibration Strategy for Texas Department of Transportation Falling Weight Deflectometer Fleet. University of Texas at El Paso. Center for Highway Materials Research, 2003, Report no. TX-01 1784-2, ROSA P. https://rosap.ntl.bts.gov/view/dot/85994.
ROSA P serves as an archival repository of USDOT-published products including scientific
findings, journal articles, guidelines, recommendations, or other information authored or co-authored by
USDOT or funded partners. As a repository, ROSA P retains documents in their original published format to
ensure public access to scientific information.
Links with this icon indicate that you are leaving a Bureau of Transportation
Statistics (BTS)/National Transportation Library (NTL)
Web-based service.
Thank you for visiting.
You are about to access a non-government link outside of
the U.S. Department of Transportation's National
Transportation Library.
Please note: While links to Web sites outside of DOT are
offered for your convenience, when you exit DOT Web sites,
Federal privacy policy and Section 508 of the Rehabilitation
Act (accessibility requirements) no longer apply. In
addition, DOT does not attest to the accuracy, relevance,
timeliness or completeness of information provided by linked
sites. Linking to a Web site does not constitute an
endorsement by DOT of the sponsors of the site or the
products presented on the site. For more information, please
view DOT's Web site linking policy.
To get back to the page you were previously viewing, click
your Cancel button.