Popovics, J. S., Roesler, J. R., Bittner, J., Amirkhanian, A. N., Brand, A. S., Gupta, P., & Flowers, K. (2017). Ultrasonic imaging for concrete infrastructure condition assessment and quality assurance (Report No. FHWA-ICT-17-007). Illinois Center for Transportation. https://rosap.ntl.bts.gov/view/dot/32225
Popovics, John S., Jeffery R. Roesler, James Bittner, Armen N. Amirkhanian, Alexander S. Brand, Prakhar Gupta, and Katherine Flowers. Ultrasonic imaging for concrete infrastructure condition assessment and quality assurance. Report no. FHWA-ICT-17-007. Illinois Center for Transportation, 2017. https://rosap.ntl.bts.gov/view/dot/32225.
Popovics, John S., et al. Ultrasonic imaging for concrete infrastructure condition assessment and quality assurance. Illinois Center for Transportation, 2017, Report no. FHWA-ICT-17-007, ROSA P. https://rosap.ntl.bts.gov/view/dot/32225.
This report describes work on laboratory and field performance reviews of an ultrasonic shear wave imaging device called MIRA
;
for application to plain and reinforced concrete infrastructure components. Potential applications investigated included bridge
;
deck delamination detection, deck thickness profiles, and detection of internal steel bars and dowels. Based on the observed
;
performance of the unit, three classification categories of applications were defined: field ready, potentially ready, and
;
challenging. In general, the MIRA device is not well suited to provide full-coverage rapid scans over an entire structure. Rather
;
MIRA is more suited for targeted inspection or failure analysis to determine general geometric and internal features of concrete
;
elements because MIRA is able to be quickly deployed for spot inspections with little site preparation. A user’s manual was
;
produced to assist in introducing new users to the proper operation and interpretation of the MIRA device.
Popovics, J. S., Roesler, J. R., Bittner, J., Amirkhanian, A. N., Brand, A. S., Gupta, P., & Flowers, K. (2017). Ultrasonic imaging for concrete infrastructure condition assessment and quality assurance (Report No. FHWA-ICT-17-007). Illinois Center for Transportation. https://rosap.ntl.bts.gov/view/dot/32225
Popovics, John S., Jeffery R. Roesler, James Bittner, Armen N. Amirkhanian, Alexander S. Brand, Prakhar Gupta, and Katherine Flowers. Ultrasonic imaging for concrete infrastructure condition assessment and quality assurance. Report no. FHWA-ICT-17-007. Illinois Center for Transportation, 2017. https://rosap.ntl.bts.gov/view/dot/32225.
Popovics, John S., et al. Ultrasonic imaging for concrete infrastructure condition assessment and quality assurance. Illinois Center for Transportation, 2017, Report no. FHWA-ICT-17-007, ROSA P. https://rosap.ntl.bts.gov/view/dot/32225.
ROSA P serves as an archival repository of USDOT-published products including scientific
findings, journal articles, guidelines, recommendations, or other information authored or co-authored by
USDOT or funded partners. As a repository, ROSA P retains documents in their original published format to
ensure public access to scientific information.
Links with this icon indicate that you are leaving a Bureau of Transportation
Statistics (BTS)/National Transportation Library (NTL)
Web-based service.
Thank you for visiting.
You are about to access a non-government link outside of
the U.S. Department of Transportation's National
Transportation Library.
Please note: While links to Web sites outside of DOT are
offered for your convenience, when you exit DOT Web sites,
Federal privacy policy and Section 508 of the Rehabilitation
Act (accessibility requirements) no longer apply. In
addition, DOT does not attest to the accuracy, relevance,
timeliness or completeness of information provided by linked
sites. Linking to a Web site does not constitute an
endorsement by DOT of the sponsors of the site or the
products presented on the site. For more information, please
view DOT's Web site linking policy.
To get back to the page you were previously viewing, click
your Cancel button.