Glass Fiber Reinforced Polymer Dowel Bar Evaluation
-
2012-09-01
Details
-
Alternative Title:Experimental Feature Project ; Post-Construction Report : Experimental Feature 10-04
-
Creators:
-
Corporate Creators:
-
Corporate Contributors:
-
Subject/TRT Terms:
-
Publication/ Report Number:
-
Resource Type:
-
Geographical Coverage:
-
Edition:Post-construction report.
-
Corporate Publisher:
-
Abstract:Glass Fiber Reinforced Polymer (GFRP) dowel bars were installed on one new construction project and two dowel bar ; retrofit projects to evaluate the performance of this type of dowel bar in comparison to steel dowel bars installed on the same ; contracts. The primary data collection site (I-82, Yakima River Br. Vic. to Granger) included 67 joints retrofit with GFRP ; dowels and an equal number of epoxy coated doweled joints that serve as the control section. ; Falling weight deflectometer (FWD) testing will be used to evaluate the load transfer efficiency (LTE) of the two types of ; dowel bars. Periodic coring of the concrete at the joints is also planned to examine the condition of the GFRP and epoxy ; coated dowels. ; Post-installation FWD testing of the primary data site revealed that the average LTE of the joints retrofit with epoxy ; coated dowel was higher than the joints retrofit with the GFRP dowels and that the difference was statistically significant. Preinstallation ; FWD testing showed no difference in the LTE of the joints in the areas where the GFRP and epoxy coated dowels ; were installed.
-
Format:
-
Funding:
-
Download URL:
-
File Type:
-
Collection(s):
-
Main Document Checksum:urn:sha256:a45c8d240f9d41403526c02df227b3f57f36dd7fc99eca734a5b8679a2582b5e