Pendulum impact testing of an impact-breakaway, windresistant base connection for multi-post ground signs.
-
2012-07-01
Details
-
Creators:
-
Corporate Creators:
-
Corporate Contributors:
-
Subject/TRT Terms:
- Signs
- Structural supports
- Impact
- Crash tests
- Crashes
- Breakaway supports
- Finite element method
- Dynamic structural analysis
- Static structural analysis
- Friction
- Sign
- Support structure
- Impact
- Collision
- Breakaway
- Finite element analysis
- Dynamic analysis
- Experimental static testing
- Structural support design specifications
- Friction
-
Publication/ Report Number:
-
Resource Type:
-
Geographical Coverage:
-
Edition:Final report; Feb. 2011-May 2012.
-
Corporate Publisher:
-
Abstract:Roadside signs play an important role in traffic control systems and must be placed adjacent to roadways. If they are not designed, ; fabricated, and installed properly, ground signs may pose potential hazards to vehicle passengers in the event of a vehicular collision with a ; sign structure. Ground signs must be strong enough to resist hurricane wind loading and self-weight, and yet sufficiently frangible to avoid ; extreme vehicular deceleration on impact. Such deceleration can cause abrupt occupant deceleration or excessive vehicle compartment ; deformation, either of which can cause serious or fatal occupant injuries. Consequently, sign structures located adjacent to roadways are ; generally designed to break away or yield under vehicle impact loading. Presently, a breakaway slip-base connection system is used in ; Florida. The breakaway mechanism of this system, however, depends on specific pretension levels in the bolts of the connection. ; Therefore, the performance of this system is undesirably sensitive to the level of bolt-torque that is imposed during installation and ; maintenance. ; In this study, a new breakaway sign post base connection, the ‘shear-controlled moment collar’, was developed and subjected to ; static and dynamic testing. The new connection system is capable of resisting code-specified equivalent static hurricane wind loads, but ; also breaks away under low energy impact (vehicular) loads. Development of the connection involved several phases: conceptual ; development using nonlinear dynamic finite element analysis; structural design; validation of wind load capacity using static experimental ; testing; and validation of breakaway performance using pendulum impact testing. Experimental determination of friction coefficients for ; Teflon sheets, used in conjunction with structural steel, was also carried out. In addition, a permanent high-energy impact pendulum test ; facility was designed and constructed as part of this research and used to conduct dynamic impact tests on the newly developed breakaway ; connection.
-
Format:
-
Funding:
-
Download URL:
-
File Type:
-
Collection(s):
-
Main Document Checksum:urn:sha256:b7d6151f711b03bb4f82e8094f912990150066a3f2ab320d1ffd82642fbdc9ad