Interstate rehabilitation with HaTelit polyester grid I-10 Sulphur-Westlake, Calcasieu Parish : interim report.
Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.

Search our Collections & Repository

All these words:

For very narrow results

This exact word or phrase:

When looking for a specific result

Any of these words:

Best used for discovery & interchangable words

None of these words:

Recommended to be used in conjunction with other fields

Language:

Dates

Publication Date Range:

to

Document Data

Title:

Document Type:

Library

Collection:

Series:

People

Author:

Help
Clear All

Query Builder

Query box

Help
Clear All

For additional assistance using the Custom Query please check out our Help Page

i

Interstate rehabilitation with HaTelit polyester grid I-10 Sulphur-Westlake, Calcasieu Parish : interim report.

Filetype[PDF-564.68 KB]


  • English

  • Details:

    • Alternative Title:
      Interstate rehabilitation with HaTelit polyester grid I-10 Sulphur-Westlake, Calcasieu Parish.
    • Publication/ Report Number:
    • Resource Type:
    • Geographical Coverage:
    • Abstract:
      This report documents the construction and initial evaluation of the HaTelit 20/9 Polyester Geogrid material placed at mid-depth of the HMAC overlay of the Broken and Seated PCC pavement on Interstate 10, west of Lake Charles, LA. The roadway has an ADT of 43,400 vpd with 20% of these being heavy trucks. This experimental feature is expected to reduce and limit the severity and extent of pavement distress.

      The material was placed between the two lifts of Binder Coarse, with an AC tack coat placed on the first lift prior to rolling the material in place. The material was also physically secured by nailing it to the previous lift. The remaining Binder along with the Wearing Coarse was placed over the material.

      The serviceability of the pavement increased after construction to an average of 4.2 PSI. Cost figures are provided and can be compared to the control sections. The performance of this experimental feature will be monitored over the next three (3) years and will be compared to the two control sections.

    • Format:
    • Main Document Checksum:
    • File Type:

    Supporting Files

    • No Additional Files

    More +