Simpson, J. W., Harik, I. E., & Choo, C. C. (2006). Shear repair of P/C box beams using carbon fiber reinforced polymer (CFRP) fabric (Report No. KTC-06-01/FRT114-01-1F). University of Kentucky Transportation Center. https://rosap.ntl.bts.gov/view/dot/21641
Simpson, Jim W., Issam E. Harik, and C. C. Choo. Shear repair of P/C box beams using carbon fiber reinforced polymer (CFRP) fabric. Report no. KTC-06-01/FRT114-01-1F. University of Kentucky Transportation Center, 2006. https://rosap.ntl.bts.gov/view/dot/21641.
Simpson, Jim W., et al. Shear repair of P/C box beams using carbon fiber reinforced polymer (CFRP) fabric. University of Kentucky Transportation Center, 2006, Report no. KTC-06-01/FRT114-01-1F, ROSA P. https://rosap.ntl.bts.gov/view/dot/21641.
The report documents the retrofit work carried out on the KY3297 Bridge over Little Sandy River in Carter County, Kentucky. Field investigation and evaluation revealed that the bridge superstructure was deficient in shear. The repair work was carried out using externally bonded carbon fiber reinforced polymer (CFRP) fabric system.
;
The repair, using externally bonded fiber system, offers the following benefits: (1) the use of light construction equipment, hand kits and tools, (2) minimal traffic disruption as all lanes were open to traffic while work was being performed underneath the bridge, and (3) cost saving; the cost for the repair and 3-years monitoring was USD $105,000.00 compared to the estimated superstructure replacement cost of USD $600,000.00.
;
The repair began in June 2001 and was completed in October 2001. After the repair, crack gauges were used to monitor all shear cracks that existed in the bridge. Inspection of the bridge was carried out at specific intervals from October 2001 to July 2005. No crack movement has been observed during the inspections. This indicates that the retrofit was a success.
Simpson, J. W., Harik, I. E., & Choo, C. C. (2006). Shear repair of P/C box beams using carbon fiber reinforced polymer (CFRP) fabric (Report No. KTC-06-01/FRT114-01-1F). University of Kentucky Transportation Center. https://rosap.ntl.bts.gov/view/dot/21641
Simpson, Jim W., Issam E. Harik, and C. C. Choo. Shear repair of P/C box beams using carbon fiber reinforced polymer (CFRP) fabric. Report no. KTC-06-01/FRT114-01-1F. University of Kentucky Transportation Center, 2006. https://rosap.ntl.bts.gov/view/dot/21641.
Simpson, Jim W., et al. Shear repair of P/C box beams using carbon fiber reinforced polymer (CFRP) fabric. University of Kentucky Transportation Center, 2006, Report no. KTC-06-01/FRT114-01-1F, ROSA P. https://rosap.ntl.bts.gov/view/dot/21641.
ROSA P serves as an archival repository of USDOT-published products including scientific
findings, journal articles, guidelines, recommendations, or other information authored or co-authored by
USDOT or funded partners. As a repository, ROSA P retains documents in their original published format to
ensure public access to scientific information.
Links with this icon indicate that you are leaving a Bureau of Transportation
Statistics (BTS)/National Transportation Library (NTL)
Web-based service.
Thank you for visiting.
You are about to access a non-government link outside of
the U.S. Department of Transportation's National
Transportation Library.
Please note: While links to Web sites outside of DOT are
offered for your convenience, when you exit DOT Web sites,
Federal privacy policy and Section 508 of the Rehabilitation
Act (accessibility requirements) no longer apply. In
addition, DOT does not attest to the accuracy, relevance,
timeliness or completeness of information provided by linked
sites. Linking to a Web site does not constitute an
endorsement by DOT of the sponsors of the site or the
products presented on the site. For more information, please
view DOT's Web site linking policy.
To get back to the page you were previously viewing, click
your Cancel button.