A precast concrete bridge bent designed to re-center after an earthquake : draft research report, August 2008.
-
2008-08-01
-
Details:
-
Alternative Title:At head of title: Draft research report, Agreement T4118, Task 05, Rapid construction, TNW 2008-06, TransNow budget no. 61-4161
-
Creators:
-
Corporate Creators:
-
Corporate Contributors:
-
Subject/TRT Terms:
-
Publication/ Report Number:
-
Resource Type:
-
Edition:Draft research report.
-
Corporate Publisher:
-
Abstract:In this study the post-earthquake residual displacements of reinforced concrete bridge bents were investigated. The system had mild steel that was intended to dissipate energy and an unbonded, post-tensioned tendon that was supposed to remain elastic and re-center the column. The columns tested had different mild steel to prestress ratios, which affected their re-centering ability. A re-centering ratio developed by Hieber (2005), which took into account the external axial load, initial prestress force, and the mild steel ratio, was used to predict these re-centering capabilities.
Two 40 percent scale specimens with large-bar connection details and a central unbonded, post-tensioned tendon were tested by using pseudo-static loading. The large-bar system is a rapidly constructible precast system for use in seismic regions. The test columns had re-centering ratios of 1.6 and 1.2. A column with the same connection details but no prestress and a re-centering ratio of 0.9 was used as a reference. The displacement at zero force in the test was used as a proxy for the residual displacement after an earthquake.
The tests showed that columns with a larger re-centering ratio did experience lower residual drifts, although this distinction only became clear for drift ratios that exceeded 2 percent. The tests also showed that increases in post-tensioning force led to slight increases in damage at high drift ratios.
-