Buck, R. E., Esposito, R. E., Gagnon, R., Leonard, E. T., & Yoh, P. (1972). Measurements and Analysis of 115 KV Power Line Noise and Its Effect on Pueblo Test Site Radio Links (Report No. DOT-TSC-FRA-72-05). United States. Department of Transportation. Federal Railroad Administration. https://rosap.ntl.bts.gov/view/dot/10442
Buck, Richard E., R. E. Esposito, R. Gagnon, E. T. Leonard, and P. Yoh. Measurements and Analysis of 115 KV Power Line Noise and Its Effect on Pueblo Test Site Radio Links. Report no. DOT-TSC-FRA-72-05. United States. Department of Transportation. Federal Railroad Administration, 1972. https://rosap.ntl.bts.gov/view/dot/10442.
Buck, Richard E., et al. Measurements and Analysis of 115 KV Power Line Noise and Its Effect on Pueblo Test Site Radio Links. United States. Department of Transportation. Federal Railroad Administration, 1972, Report no. DOT-TSC-FRA-72-05, ROSA P. https://rosap.ntl.bts.gov/view/dot/10442.
Noise measurements were made for 115 KV power lines near the frequencies 166, 217 and 406.8 MHz with a receiver bandwidth of 1 MHz. The measurements consisted of counting the numbers of pulses per minute at preset threshold values and RMS. The variations of the noise level vs the lateral distance from the power line were also measured. The worst noise level, -40 dBm, was observed at 217 MHz under a noisy power line. The results of these measurements show that, under normal conditions, power line noise will not have significant effects on the radio links at the Pueblo Test Site.
Buck, R. E., Esposito, R. E., Gagnon, R., Leonard, E. T., & Yoh, P. (1972). Measurements and Analysis of 115 KV Power Line Noise and Its Effect on Pueblo Test Site Radio Links (Report No. DOT-TSC-FRA-72-05). United States. Department of Transportation. Federal Railroad Administration. https://rosap.ntl.bts.gov/view/dot/10442
Buck, Richard E., R. E. Esposito, R. Gagnon, E. T. Leonard, and P. Yoh. Measurements and Analysis of 115 KV Power Line Noise and Its Effect on Pueblo Test Site Radio Links. Report no. DOT-TSC-FRA-72-05. United States. Department of Transportation. Federal Railroad Administration, 1972. https://rosap.ntl.bts.gov/view/dot/10442.
Buck, Richard E., et al. Measurements and Analysis of 115 KV Power Line Noise and Its Effect on Pueblo Test Site Radio Links. United States. Department of Transportation. Federal Railroad Administration, 1972, Report no. DOT-TSC-FRA-72-05, ROSA P. https://rosap.ntl.bts.gov/view/dot/10442.
ROSA P serves as an archival repository of USDOT-published products including scientific
findings, journal articles, guidelines, recommendations, or other information authored or co-authored by
USDOT or funded partners. As a repository, ROSA P retains documents in their original published format to
ensure public access to scientific information.
Links with this icon indicate that you are leaving a Bureau of Transportation
Statistics (BTS)/National Transportation Library (NTL)
Web-based service.
Thank you for visiting.
You are about to access a non-government link outside of
the U.S. Department of Transportation's National
Transportation Library.
Please note: While links to Web sites outside of DOT are
offered for your convenience, when you exit DOT Web sites,
Federal privacy policy and Section 508 of the Rehabilitation
Act (accessibility requirements) no longer apply. In
addition, DOT does not attest to the accuracy, relevance,
timeliness or completeness of information provided by linked
sites. Linking to a Web site does not constitute an
endorsement by DOT of the sponsors of the site or the
products presented on the site. For more information, please
view DOT's Web site linking policy.
To get back to the page you were previously viewing, click
your Cancel button.