McKubre, M. (2003). Silver-Sulfur Deposits on Fuel Quantity Indication System and Attendant Wiring (Report No. DOT/FAA/AR-03/61). United States. Department of Transportation. Federal Aviation Administration. William J. Hughes Technical Center. https://rosap.ntl.bts.gov/view/dot/94484
McKubre, Michael. Silver-Sulfur Deposits on Fuel Quantity Indication System and Attendant Wiring. Report no. DOT/FAA/AR-03/61. United States. Department of Transportation. Federal Aviation Administration. William J. Hughes Technical Center, 2003. https://rosap.ntl.bts.gov/view/dot/94484.
McKubre, Michael Silver-Sulfur Deposits on Fuel Quantity Indication System and Attendant Wiring. United States. Department of Transportation. Federal Aviation Administration. William J. Hughes Technical Center, 2003, Report no. DOT/FAA/AR-03/61, ROSA P. https://rosap.ntl.bts.gov/view/dot/94484.
This report describes the results of a 3-year program to explain potential problems in aircraft fuel tanks caused by the presence of electrically conductive deposits containing sulfur and metal. A significant conclusion of the work described herein is that the active and harmful inorganic component of the deposits is silver oxide; the roles of copper and sulfur both appear to be secondary and to suppress conductivity. The electrical properties of deposits formed naturally in fuel tanks, or grown under representative laboratory conditions, can cause misreading in presently employed electrical fuel quantification systems. The chemical and electrochemical properties of silver oxide-derived deposits can contribute a potential ignition hazard by two mechanisms studied and analyzed in this report.
McKubre, M. (2003). Silver-Sulfur Deposits on Fuel Quantity Indication System and Attendant Wiring (Report No. DOT/FAA/AR-03/61). United States. Department of Transportation. Federal Aviation Administration. William J. Hughes Technical Center. https://rosap.ntl.bts.gov/view/dot/94484
McKubre, Michael. Silver-Sulfur Deposits on Fuel Quantity Indication System and Attendant Wiring. Report no. DOT/FAA/AR-03/61. United States. Department of Transportation. Federal Aviation Administration. William J. Hughes Technical Center, 2003. https://rosap.ntl.bts.gov/view/dot/94484.
McKubre, Michael Silver-Sulfur Deposits on Fuel Quantity Indication System and Attendant Wiring. United States. Department of Transportation. Federal Aviation Administration. William J. Hughes Technical Center, 2003, Report no. DOT/FAA/AR-03/61, ROSA P. https://rosap.ntl.bts.gov/view/dot/94484.
ROSA P serves as an archival repository of USDOT-published products including scientific
findings, journal articles, guidelines, recommendations, or other information authored or co-authored by
USDOT or funded partners. As a repository, ROSA P retains documents in their original published format to
ensure public access to scientific information.
Links with this icon indicate that you are leaving a Bureau of Transportation
Statistics (BTS)/National Transportation Library (NTL)
Web-based service.
Thank you for visiting.
You are about to access a non-government link outside of
the U.S. Department of Transportation's National
Transportation Library.
Please note: While links to Web sites outside of DOT are
offered for your convenience, when you exit DOT Web sites,
Federal privacy policy and Section 508 of the Rehabilitation
Act (accessibility requirements) no longer apply. In
addition, DOT does not attest to the accuracy, relevance,
timeliness or completeness of information provided by linked
sites. Linking to a Web site does not constitute an
endorsement by DOT of the sponsors of the site or the
products presented on the site. For more information, please
view DOT's Web site linking policy.
To get back to the page you were previously viewing, click
your Cancel button.