Electrochemical Testing of Lightweight Aggregates for MSE Wall Fill
Details
-
Creators:
-
Corporate Creators:
-
Corporate Publisher:
-
Contributor:
-
Corporate Contributors:
-
Subject/TRT Terms:
-
Publication/ Report Number:
-
Resource Type:
-
Geographical Coverage:
-
Edition:Final Report
-
Description:Lightweight aggregates (LWAs), including expanded shale and foamed glass aggregate (FGA), are increasingly considered as alternative backfill materials for mechanically stabilized earth (MSE) walls due to their favorable engineering properties. However, questions remain regarding the applicability of conventional electrochemical test methods to LWAs and the interpretation of test results relative to corrosion performance of metallic reinforcements. This study was sponsored by PennDOT to evaluates the electrochemical characteristics of four LWAs, listed in PennDOT Bulletin 14 and Bulletin 15, through sulfate, chloride, pH, and electrical resistivity testing. Testing was conducted using both standard AASHTO and PennDOT procedures and modified testing approaches to examine the influence of extraction methods, particle size, moisture condition, gradation, and compaction on measured results. Results indicate that sulfate and chloride measurements are strongly influenced by extraction protocol and particle size, with aggressive extraction producing higher measured ion concentrations. Chloride contents were generally low, while sulfate values for certain materials approached specification limits. pH values were generally moderately alkaline, although finer fractions occasionally exceeded specification ranges, indicating the importance of considering gradation effects during evaluation. Electrical resistivity testing demonstrated that all LWAs exhibit high resistivity relative to specification thresholds and that resistivity is strongly affected by moisture content, compaction, and drainage behavior. Laboratory resistivity values may represent upper-bound conditions relative to field performance due to differences in compaction. Overall, the results support the suitability of LWAs for MSE wall applications when evaluated using appropriate testing procedures. Recommendations are provided regarding sample preparation, interpretation of electrochemical tests, and resistivity testing protocols to improve consistency and applicability of laboratory evaluations.
-
Format:
-
Funding:
-
Download URL:
-
File Type:
-
Collection(s):
-
Main Document Checksum:urn:sha-512:69a59fc9b87529d3cc12dcd768c0c9e5c7dc614d9e3967d08fe6ad84fb65a13024865f66e7e1395a523c67d201496199fa7ee84d76897b91c209a1263c870c09