Task 4: UN Series 6 testing of non-exploding, large-scale thermites, large-scale mix ID #3. For many years, the properties of thermites have perplexed test laboratories and regulators; one thermite manufacturer published on their website that they had provided a sample of their thermite to a well-known and respected international test laboratory that performed the UN Test N.1 Flammable solids test on the sample, only to have the thermite pass the test criteria; it was the conclusion of the test laboratory that the thermite was non-regulated for transport. Manufacturers, testing laboratories and regulators have been struggling together with the proper characterization and classification of thermites. U.S. DOT PHMSA, taking a very rational but extremely unpopular position, began regulating thermites, since they were being manufactured with the view to producing a pyrotechnic effect, under the same classification system as explosives.
Content Notes:
U.S. DOT PHMSA publicly released Safety Management Services’ Thermite Research Report on April 16, 2024. The report and supporting videos are available as part of the Thermites series.
For many years, the properties of thermites have perplexed test laboratories and regulators; one thermite manufacturer published on their website that...
Thermite Mixes 1-8, Sub-Scale UN Series 7(e) EIS External Fire, Test Setup. For many years, the properties of thermites have perplexed test laboratori...
Task 5: full-scale testing of commercial thermite in transport configurations. For many years, the properties of thermites have perplexed test laborat...
Links with this icon indicate that you are leaving a Bureau of Transportation
Statistics (BTS)/National Transportation Library (NTL)
Web-based service.
Thank you for visiting.
You are about to access a non-government link outside of
the U.S. Department of Transportation's National
Transportation Library.
Please note: While links to Web sites outside of DOT are
offered for your convenience, when you exit DOT Web sites,
Federal privacy policy and Section 508 of the Rehabilitation
Act (accessibility requirements) no longer apply. In
addition, DOT does not attest to the accuracy, relevance,
timeliness or completeness of information provided by linked
sites. Linking to a Web site does not constitute an
endorsement by DOT of the sponsors of the site or the
products presented on the site. For more information, please
view DOT's Web site linking policy.
To get back to the page you were previously viewing, click
your Cancel button.