Laboratory Evaluation of Existing Breakaway Structures – Volume III – Test Data
-
1979-10-01
Details:
-
Creators:
-
Corporate Creators:
-
Contributors:
-
Corporate Contributors:
-
Subject/TRT Terms:
-
Publication/ Report Number:
-
Resource Type:
-
Geographical Coverage:
-
Edition:Final Report
-
Contracting Officer:
-
Corporate Publisher:
-
Abstract:A whole array of existing breakaway luminaire supports were tested using the FHWA soft-nosed pendulum test device. The pendulum was developed to simulate a subcompact car behavior. This nose was properly validated against full- scale test data. Due to unacceptable impact performance, modifications were made to cast aluminum transformer bases to reduce momentum change levels. Performance was greatly improved. The FHWA bogie test device was built and validated for use in testing dual-legged breakaway sign supports. Full scale tests were run to provide full-scale validation data and to study off-center hit problems. This is the third of three volumes. This volume contains test data only. Volume I is an Executive Summary while Volume II contains the technical results of the project.
-
Format:
-
Funding:
-
Collection(s):
-
Main Document Checksum:
-
Download URL:
-
File Type: