Evaluation of Lightweight Aggregate for Internal Curing on Concrete Pavement in Kansas
Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.

Search our Collections & Repository

All these words:

For very narrow results

This exact word or phrase:

When looking for a specific result

Any of these words:

Best used for discovery & interchangable words

None of these words:

Recommended to be used in conjunction with other fields

Language:

Dates

Publication Date Range:

to

Document Data

Title:

Document Type:

Library

Collection:

Series:

People

Author:

Help
Clear All

Query Builder

Query box

Help
Clear All

For additional assistance using the Custom Query please check out our Help Page

i

Evaluation of Lightweight Aggregate for Internal Curing on Concrete Pavement in Kansas

Filetype[PDF-11.13 MB]


Select the Download button to view the document
This document is over 5mb in size and cannot be previewed
  • English

  • Details:

    • Publication/ Report Number:
    • Resource Type:
    • Edition:
      Final
    • Abstract:
      The purpose of this project and the Internally Cured Concrete (ICC) test section was to evaluate the benefits obtained through internal curing using pre-saturated lightweight aggregate (LWA). Two test sections were constructed on the mainline of US-54 near Iola, Kansas: a Control section and an ICC section using lightweight aggregate. Traditional laboratory testing was conducted on each test section to compare fresh and hardened concrete properties including, but not limited to, slump, temperature, air content, unit weight, strength, permeability, and freeze/thaw. Also, several strain gages and moisture sensors were embedded in each test section to monitor the actual strain and moisture content present in the concrete. In addition, a Dipstick Profiler was used on five panels to get a full panel surface profile at the highest and lowest temperatures for several days after pavement construction. Last, HIPERPAV III analysis was used to compare early age stress and cracking risk. The plastic and hardened concrete results presented in this report indicate no significant impact of the LWA material. For the majority of the properties tested, when comparing the results from the two sections, the values fall within the multiple laboratory precision expected when testing from the same concrete batch. However, the reduction in unit weight, the slight reduction of elastic modulus, and the slight increase in tensile strength of the ICC indicate a potential improvement in overall durability and potentially increased service life. Additional research into these properties would be required to support that data. The methods used to collect strain, moisture, and deflection data were highly successful. All methods of data collection including strain, curvature, moisture, deflection, and HIPERPAV III results infer the use of lightweight aggregate and internally cured concrete reduce the initial strain and undesirable deformations in the concrete. However, the test sections were not able to be constructed at the same time due to lack of staff, weather delays, and contractor’s schedule, and therefore, were constructed 3 months apart. As a result, the significant weather differences between the placement dates have been observed to have impacted the data from the strain gages and moisture sensors. Therefore, it cannot be concluded with certainty if the use of LWA in the ICC improved the quality and durability of the concrete compared to the Control section. General condition surveys will be performed every five years of the 20-year design life, or until a major rehabilitation occurs and the original sections can no longer be surveyed.
    • Format:
    • Main Document Checksum:
    • File Type:

    Supporting Files

    • No Additional Files

    More +

    Related Documents

    You May Also Like

    Checkout today's featured content at rosap.ntl.bts.gov

    Version 3.26