Acoustic Emission Monitoring of North East Trunnion Shaft on Oregon DOT Bridge 1377A I-5 Over the Columbia River, Portland, Oregon
-
1996-05-01
Details:
-
Creators:
-
Corporate Creators:
-
Subject/TRT Terms:
-
Publication/ Report Number:
-
Resource Type:
-
Geographical Coverage:
-
Corporate Publisher:
-
NTL Classification:NTL-HIGHWAY/ROAD TRANSPORTATION-Bridges and Structures
-
Abstract:Acoustic emission monitoring has been used to provide additional confirmation that ultrasonic indications in a forged trunnion shaft are active fatigue cracks. An advanced all digital AE monitoring system developed by Vallen Systeme GmbH of Icking Germany was applied in a setup that used linear location and guard channels. A unique signal processing approach that combines both spatial and temporal clustering was used to eliminate the large amount of
background noise present during the tests.
-