Thiele, J. C., Lechtenberg, K. A., Reid, J. D., Faller, R. K., Sicking, D. L., & Bielenberg, R. W. (2009). Performance Limits for 6-in. (152-Mm) High Curbs Placed in Advance of the MGS Using MASH Vehicles: Part II, Full-Scale Crash Testing (Report No. TRP-03-221-09). Midwest States Regional Pooled Fund Program. https://rosap.ntl.bts.gov/view/dot/39840
Thiele, Jeffrey C., Karla A. Lechtenberg, John D. Reid, Ronald K. Faller, Dean L. Sicking, and Robert W. Bielenberg. Performance Limits for 6-in. (152-Mm) High Curbs Placed in Advance of the MGS Using MASH Vehicles: Part II, Full-Scale Crash Testing. Report no. TRP-03-221-09. Midwest States Regional Pooled Fund Program, 2009. https://rosap.ntl.bts.gov/view/dot/39840.
Thiele, Jeffrey C., et al. Performance Limits for 6-in. (152-Mm) High Curbs Placed in Advance of the MGS Using MASH Vehicles: Part II, Full-Scale Crash Testing. Midwest States Regional Pooled Fund Program, 2009, Report no. TRP-03-221-09, ROSA P. https://rosap.ntl.bts.gov/view/dot/39840.
A full-scale crash test using Manual for Assessing Safety Hardware (MASH) Test Level 3 (TL-3) criteria was performed on the Midwest Guardrail System (MGS) offset 8 ft (2.44 m) behind a 6-in. (152-mm) high AASHTO Type B curb with a top mounting height of 31 in. (787 mm) relative to the ground 37 in. (940 mm) relative to the roadway. In the test, the vehicle was contained by the guardrail, but became unstable and rolled over. Analysis of the test revealed that the right-front tire snagged on a post and detached. The right-rear tire of the pickup traversed over the detached tire, causing the rear of the vehicle to pitch upward. The vehicle subsequently became unstable and rolled over. Thus, the MGS offset 8 ft (2.44 mm) behind a 6-in. (152-mm) high curb with a top mounting height of 31 in. (787 mm) was deemed to be unacceptable according to TL-3 of MASH.
Thiele, J. C., Lechtenberg, K. A., Reid, J. D., Faller, R. K., Sicking, D. L., & Bielenberg, R. W. (2009). Performance Limits for 6-in. (152-Mm) High Curbs Placed in Advance of the MGS Using MASH Vehicles: Part II, Full-Scale Crash Testing (Report No. TRP-03-221-09). Midwest States Regional Pooled Fund Program. https://rosap.ntl.bts.gov/view/dot/39840
Thiele, Jeffrey C., Karla A. Lechtenberg, John D. Reid, Ronald K. Faller, Dean L. Sicking, and Robert W. Bielenberg. Performance Limits for 6-in. (152-Mm) High Curbs Placed in Advance of the MGS Using MASH Vehicles: Part II, Full-Scale Crash Testing. Report no. TRP-03-221-09. Midwest States Regional Pooled Fund Program, 2009. https://rosap.ntl.bts.gov/view/dot/39840.
Thiele, Jeffrey C., et al. Performance Limits for 6-in. (152-Mm) High Curbs Placed in Advance of the MGS Using MASH Vehicles: Part II, Full-Scale Crash Testing. Midwest States Regional Pooled Fund Program, 2009, Report no. TRP-03-221-09, ROSA P. https://rosap.ntl.bts.gov/view/dot/39840.
ROSA P serves as an archival repository of USDOT-published products including scientific
findings, journal articles, guidelines, recommendations, or other information authored or co-authored by
USDOT or funded partners. As a repository, ROSA P retains documents in their original published format to
ensure public access to scientific information.
Links with this icon indicate that you are leaving a Bureau of Transportation
Statistics (BTS)/National Transportation Library (NTL)
Web-based service.
Thank you for visiting.
You are about to access a non-government link outside of
the U.S. Department of Transportation's National
Transportation Library.
Please note: While links to Web sites outside of DOT are
offered for your convenience, when you exit DOT Web sites,
Federal privacy policy and Section 508 of the Rehabilitation
Act (accessibility requirements) no longer apply. In
addition, DOT does not attest to the accuracy, relevance,
timeliness or completeness of information provided by linked
sites. Linking to a Web site does not constitute an
endorsement by DOT of the sponsors of the site or the
products presented on the site. For more information, please
view DOT's Web site linking policy.
To get back to the page you were previously viewing, click
your Cancel button.