Unintentional freeze-ups can cause a considerable amount of damage to a building's mechanical and architectural components resulting in costly repairs and the temporary loss of the facility's usage. The major complement of freeze-ups occur in unattended buildings as a result of heating unit failures. In many cases, buildings and content damage could be eliminated if simple alarm systems were available to give maintenance personnel advance warning of abnormally low temperatures. This report, along with an earlier one entitled "Design Report--Building Freeze Alarm System" (AK-RD-83-10) describes design considerations of VHF radio alarm systems and tests performed on 3 prototype units. Assembled primarily from off-the-shelf components, these 2 to 25 watt units can be expected to provide reliable freeze protection under a wide variety of installation conditions. In addition to freeze protection, the units can be easily modified to be activated by any switch closure type sensor.
Merritt, R. P., Strandberg, J. S., & Merritt, C. (1983). Building Freeze Alarm Systems. Test Report (Report No. AK-RD-83-25). Alaska. Dept. of Transportation and Public Facilities. https://rosap.ntl.bts.gov/view/dot/38864
Merritt, Robert P., James S. Strandberg, and Christopher Merritt. Building Freeze Alarm Systems. Test Report. Report no. AK-RD-83-25. Alaska. Dept. of Transportation and Public Facilities, 1983. https://rosap.ntl.bts.gov/view/dot/38864.
Merritt, Robert P., et al. Building Freeze Alarm Systems. Test Report. Alaska. Dept. of Transportation and Public Facilities, 1983, Report no. AK-RD-83-25, ROSA P. https://rosap.ntl.bts.gov/view/dot/38864.
ROSA P serves as an archival repository of USDOT-published products including scientific
findings, journal articles, guidelines, recommendations, or other information authored or co-authored by
USDOT or funded partners. As a repository, ROSA P retains documents in their original published format to
ensure public access to scientific information.
Links with this icon indicate that you are leaving a Bureau of Transportation
Statistics (BTS)/National Transportation Library (NTL)
Web-based service.
Thank you for visiting.
You are about to access a non-government link outside of
the U.S. Department of Transportation's National
Transportation Library.
Please note: While links to Web sites outside of DOT are
offered for your convenience, when you exit DOT Web sites,
Federal privacy policy and Section 508 of the Rehabilitation
Act (accessibility requirements) no longer apply. In
addition, DOT does not attest to the accuracy, relevance,
timeliness or completeness of information provided by linked
sites. Linking to a Web site does not constitute an
endorsement by DOT of the sponsors of the site or the
products presented on the site. For more information, please
view DOT's Web site linking policy.
To get back to the page you were previously viewing, click
your Cancel button.