Long-term post-tensioned beam exposure test specimens : final evaluation.
-
2003-08-01
Details
-
Creators:
-
Corporate Creators:
-
Corporate Contributors:
-
Subject/TRT Terms:
-
Publication/ Report Number:
-
Resource Type:
-
Geographical Coverage:
-
Corporate Publisher:
-
Abstract:In the last few years, the effectiveness of cement grout in galvanized or polyethylene ducts, the most widely used corrosion protection system for ; multistrand bonded post-tensioned concrete tendons, has been under debate, due to significant tendon corrosion damage, several reported failures ; of individual tendons as well as a few collapses of non-typical structures. While experience in the USA has been generally good, some foreign ; experience has been less than satisfactory. ; This report is part of a comprehensive research program started in 1993, which has the objectives to examine the use of post-tensioning in bridge ; substructures, identify durability concerns and existing technology, develop and carry out an experimental testing program, and conclude with ; durability design guidelines. ; Three experimental programs were developed: A long term macrocell corrosion test series, to investigate corrosion protection for internal ; tendons in precast segmental construction; a long term beam corrosion test series, to examine the effects of post-tensioning on corrosion ; protection as affected by crack width; and, a long term column corrosion test series, to examine corrosion protection in vertical elements. ; Preliminary design guidelines were developed previously in the overall study by the initial researchers, after an extensive literature review. ; This report documents the final evaluation of the long-term post-tensioned beam exposure test specimens, after comprehensive autopsies ; of selected beams and updating the durability design guidelines based on the exposure testing and autopsy results. ; After autopsies were performed, overall findings indicate negative durability effects due to the use of mixed reinforcement, galvanized ; steel ducts, and industry standard or heat-shrink galvanized duct splices. The width of cracks was shown to have a direct negative effect ; on specimen performance. Grout voids were found to be detrimental to the durability of both galvanized ducts and strand. On the other ; hand, very positive effects were found with the use of high performance concrete, high post-tensioning levels, and plastic ducts.
-
Format:
-
Funding:
-
Download URL:
-
File Type:
-
Collection(s):
-
Main Document Checksum:urn:sha256:bb95c224eea8936aeb848024a328faf95102e699e740bf9a04cd82de43367ab1