U.S. flag An official website of the United States government.
Official websites use .gov

A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS

A lock ( ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

i

Investigation of field corrosion performance and bond/development length of galvanized reinforcing steel.

File Language:
English


Details

  • Creators:
  • Corporate Creators:
  • Corporate Contributors:
  • Subject/TRT Terms:
  • Publication/ Report Number:
  • Resource Type:
  • Geographical Coverage:
  • Corporate Publisher:
  • Abstract:
    In reinforced concrete systems, ensuring that a good bond between the concrete and the embedded reinforcing steel is critical to

    long-term structural performance. Without good bond between the two, the system simply cannot behave as intended. The bond

    strength of reinforcing bars is a complex interaction between localized deformations, chemical adhesion, and other factors.

    Coating of reinforcing bars, although sometimes debated, has been commonly found to be an effective way to delay the initiation

    of corrosion in reinforced concrete systems.

    For many years, the standard practice has been to coat reinforcing steel with an epoxy coating, which provides a barrier between

    the steel and the corrosive elements of water, air, and chloride ions. Recently, there has been an industry-led effort to use

    galvanizing to provide the protective barrier commonly provided by traditional epoxy coatings. However, as with any new

    structural product, questions exist regarding both the structural performance and corrosion resistance of the system.

    In the fall of 2013, Buchanan County, Iowa constructed a demonstration bridge in which the steel girders and all internal

    reinforcing steel were galvanized. The work completed in this project sought to understand the structural performance of

    galvanized reinforcing steel as compared to epoxy-coated steel and to initiate a long-term corrosion monitoring program. This

    work consisted of a series of controlled laboratory tests and the installation of a corrosion monitoring system that can be observed

    for years in the future.

    The results of this work indicate there is no appreciable difference between the bond strength of epoxy-coated reinforcing steel

    and galvanized reinforcing steel. Although some differences were observed, no notable difference in either peak load, slip, or

    failure mode could be identified. Additionally, a long-term monitoring system was installed in this Buchanan County bridge and,

    to date, no corrosion activity has been identified.

  • Format:
  • Collection(s):
  • Main Document Checksum:
    urn:sha-512:b22cd42adcd78db998a1ee599bf48ac4c6c7a947eb6bebde869050c07c1b46e02b2b37b013afba45a0177a64a72d078d2a224697b5f2461f04bc4600900ac4f5
  • Download URL:
  • File Type:
    Filetype[PDF - 1.19 MB ]
File Language:
English
ON THIS PAGE

ROSA P serves as an archival repository of USDOT-published products including scientific findings, journal articles, guidelines, recommendations, or other information authored or co-authored by USDOT or funded partners. As a repository, ROSA P retains documents in their original published format to ensure public access to scientific information.