Funkhouser, G. E., & Fairlie, G. W. (1991). Donning Times and Flotation Characteristics of Infant Life Preservers: Four Representative Types (Report No. DOT/FAA/AM-91/6). Civil Aerospace Medical Institute. https://rosap.ntl.bts.gov/view/dot/21335
Funkhouser, Gordon E. and Gregory W. Fairlie. Donning Times and Flotation Characteristics of Infant Life Preservers: Four Representative Types. Report no. DOT/FAA/AM-91/6. Civil Aerospace Medical Institute, 1991. https://rosap.ntl.bts.gov/view/dot/21335.
Funkhouser, Gordon E., and Gregory W. Fairlie Donning Times and Flotation Characteristics of Infant Life Preservers: Four Representative Types. Civil Aerospace Medical Institute, 1991, Report no. DOT/FAA/AM-91/6, ROSA P. https://rosap.ntl.bts.gov/view/dot/21335.
Four currently available representative types of infant life preservers were tested to assess the donning times and flotation characteristics for infant subjects(6 months to 2 years old). Two of the four devices tested were fixed-foam recreational devices and two were inflatable, dual-chambered devices that met TSO C-13d requirements. The parent received video-taped donning instructions prior to the timed donning trials. Donning times were recorded from the time the unwrapped device was handed to the parent until the last connection or adjustment was made. The device that was most quickly donned was an inflatable type with a vest attached to the top of the upper chamber (median donning time was 28.8 seconds). This infant life preserver also exhibited good body support with the head well above the water. The two fixed-foam devices were designed to have approximately one-third of the buoyancy of the two inflatable types and relied on assistance from an adult to maintain the infant in a safe flotation attitude. It appears that the fixed-foam infant 5 life preservers would provide more thermal protection than the inflatable life preservers.
Funkhouser, G. E., & Fairlie, G. W. (1991). Donning Times and Flotation Characteristics of Infant Life Preservers: Four Representative Types (Report No. DOT/FAA/AM-91/6). Civil Aerospace Medical Institute. https://rosap.ntl.bts.gov/view/dot/21335
Funkhouser, Gordon E. and Gregory W. Fairlie. Donning Times and Flotation Characteristics of Infant Life Preservers: Four Representative Types. Report no. DOT/FAA/AM-91/6. Civil Aerospace Medical Institute, 1991. https://rosap.ntl.bts.gov/view/dot/21335.
Funkhouser, Gordon E., and Gregory W. Fairlie Donning Times and Flotation Characteristics of Infant Life Preservers: Four Representative Types. Civil Aerospace Medical Institute, 1991, Report no. DOT/FAA/AM-91/6, ROSA P. https://rosap.ntl.bts.gov/view/dot/21335.
ROSA P serves as an archival repository of USDOT-published products including scientific
findings, journal articles, guidelines, recommendations, or other information authored or co-authored by
USDOT or funded partners. As a repository, ROSA P retains documents in their original published format to
ensure public access to scientific information.
Links with this icon indicate that you are leaving a Bureau of Transportation
Statistics (BTS)/National Transportation Library (NTL)
Web-based service.
Thank you for visiting.
You are about to access a non-government link outside of
the U.S. Department of Transportation's National
Transportation Library.
Please note: While links to Web sites outside of DOT are
offered for your convenience, when you exit DOT Web sites,
Federal privacy policy and Section 508 of the Rehabilitation
Act (accessibility requirements) no longer apply. In
addition, DOT does not attest to the accuracy, relevance,
timeliness or completeness of information provided by linked
sites. Linking to a Web site does not constitute an
endorsement by DOT of the sponsors of the site or the
products presented on the site. For more information, please
view DOT's Web site linking policy.
To get back to the page you were previously viewing, click
your Cancel button.