Evaluation of two corrosion inhibitors using two surface application methods for reinforced concrete structures.
-
2004-01-01
Details:
-
Creators:
-
Corporate Creators:
-
Subject/TRT Terms:
-
Publication/ Report Number:
-
Resource Type:
-
Geographical Coverage:
-
Edition:Final report;July 1, 2003Nov. 30, 2004.
-
Corporate Publisher:
-
Abstract:This study investigated the use of penetrating corrosion inhibitors to extend the life of existing reinforced concrete bridge decks. The use of assisted (vacuum/pressure injection) and unassisted (diffusion) treatment methods and two inhibitors were evaluated. The inhibitors were FerroGard 903, from Sika Corp., and TPS-II, from Surtreat International. Testing was performed on exposure slabs with 15 lb/yd3 of NaCl in the top layer and no NaCl in the bottom layer. The slab design was a variation of the specimen design provided in ASTM G109, with each slab containing nine steel reinforcing rods instead of three. The exposure slabs had either a uniform cover over the top pieces of steel or an inclined cover over the steel. TPS-II was also evaluated on the deck of a bridge in Orange County, Virginia. The study found that when applied to the concrete surface, neither inhibitor penetrated the concrete to reach the steel reinforcement. The vacuum/pressure injection method showed promise but requires refinement. In addition, based on macro-cell measurements, a sufficient quantity of inhibitor can be injected into the concrete to reduce the charge passed.
-
Format:
-
Collection(s):
-
Main Document Checksum:
-
File Type:
Supporting Files
-
No Additional Files
More +