U.S. flag An official website of the United States government.
Official websites use .gov

A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS

A lock ( ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

i

Field evaluation of corrosion inhibitors for concrete. Interim report 1, Evaluation of exposure slabs repaired with corrosion inhibitors.

File Language:
English


Details

  • Alternative Title:
    Evaluation of exposure slabs repaired with corrosion inhibitors
  • Creators:
  • Corporate Creators:
  • Subject/TRT Terms:
  • Publication/ Report Number:
  • Resource Type:
  • Geographical Coverage:
  • Edition:
    Interim report.
  • Corporate Publisher:
  • Abstract:
    One hundred and fifty-six exposure slabs have been constructed with and without a variety of combinations of corrosion inhibiting admixtures and topically applied inhibitors. To accelerate corrosion one hundred and thirty-six of the slabs were constructed with concrete that surrounded the top mat of reinforcement with chloride contents of 3,6, 10, and 15 Ib/yd³ (1.8,3.5,5.9, and 8.9 kg/m³). This paper presents the results from measurements made on the slabs in May 1998 after approximately 1 year of exposure. The measurements show that as the chloride ion content in the slabs increases, the macrocell current, macrocell potential, half-cell potential, and rate of corrosion increase and the resistance decreases. Macrocell currents exceed 10 uA, indicating corrosion activity, in slabs cast with chloride in the concrete except those with 3 Ib/yd³ (1.8 kg/m³ ) of chloride that were overlayed and patched or patched. Measurements taken to determine the rate of corrosion indicate high, moderate, low, and passive states of corrosion in 63,22, 12, and 3 percent, respectively, of the slabs. The measurements also show no significant difference between the slabs repaired with and without corrosion inhibitor admixtures and topical treatments. Slabs repaired with 7% silica fume showed half-cell potentials that were less negative than those repaired without silica fume.
  • Format:
  • Collection(s):
  • Main Document Checksum:
    urn:sha256:d05a74333c502c0b72bc8c8f44b908db347f192fce9c05bdd24f40ab04155c59
  • Download URL:
  • File Type:
    Filetype[PDF - 2.70 MB ]
File Language:
English
ON THIS PAGE

ROSA P serves as an archival repository of USDOT-published products including scientific findings, journal articles, guidelines, recommendations, or other information authored or co-authored by USDOT or funded partners. As a repository, ROSA P retains documents in their original published format to ensure public access to scientific information.