Virginia's first installation of epoxy-coated reinforcing steel, which was opened to traffic in 1977, was evaluated during construction and through 13 years of service. It was apparent at the time of construction that the integrity of the coating application did not meet the requirements of the specifications There were many flaws and holidays in the coatings on all of the bars, and patching with a liquid epoxy compound was not effective. Although the applicability of the findings, which are based on an application that does not represent the best practice, may be limited, useful information on the durability of the coated steel and its role in protecting the deck was developed. It was found that the coated reinforcement was exposed to relatively high chloride concentrations at transverse cracks in the decks early in the life of the structures, but the decks remained in good condition throughout the evaluation period. It was concluded that despite the poor coatings, the coated reinforcing steel contributed to the deck's durability by providing enhanced protection at critical cracked sections. Rebars taken from deck cores showed no signs of rusting, although the steel had a dull dark gray finish that may be underfilm corrosion. No debonding of the coating was evident.
The existing test method used to assess the corrosion performance of reinforcing steel embedded inconcrete, mainly ASTM G 109, is labor intensive, tim...
Applying a temporary electric field between the concrete surface and the rebars can expel or remove chloride ions from salt-contaminated reinforced co...
Links with this icon indicate that you are leaving a Bureau of Transportation
Statistics (BTS)/National Transportation Library (NTL)
Web-based service.
Thank you for visiting.
You are about to access a non-government link outside of
the U.S. Department of Transportation's National
Transportation Library.
Please note: While links to Web sites outside of DOT are
offered for your convenience, when you exit DOT Web sites,
Federal privacy policy and Section 508 of the Rehabilitation
Act (accessibility requirements) no longer apply. In
addition, DOT does not attest to the accuracy, relevance,
timeliness or completeness of information provided by linked
sites. Linking to a Web site does not constitute an
endorsement by DOT of the sponsors of the site or the
products presented on the site. For more information, please
view DOT's Web site linking policy.
To get back to the page you were previously viewing, click
your Cancel button.