McGhee, K. H. (1992). Evaluation of a K.J. Law model 8300 ultrasonic roughness testing device (Report No. FHWA/VA-93R3). Virginia Transportation Research Council (VTRC). https://rosap.ntl.bts.gov/view/dot/19325
McGhee, Kenneth H. Evaluation of a K.J. Law model 8300 ultrasonic roughness testing device. Report no. FHWA/VA-93R3. Virginia Transportation Research Council (VTRC), 1992. https://rosap.ntl.bts.gov/view/dot/19325.
McGhee, Kenneth H Evaluation of a K.J. Law model 8300 ultrasonic roughness testing device. Virginia Transportation Research Council (VTRC), 1992, Report no. FHWA/VA-93R3, ROSA P. https://rosap.ntl.bts.gov/view/dot/19325.
A study of the KJ. Law Model 8300 Roughness Surveyor was begun in 1985 to determine the feasibility of replacing Mays Meter roughness testing equipment with an easier to use and more repeatable alternative. The original schedule called for completion of the study in late 1986. However, the study was badly delayed because of equipment failures, long delays by the manufacturer when the equipment was returned for trouble shooting, and altered priorities placed on the research staff: Because of these altered priorities, the study was tabled for several years so that final testing was not completed until mid-1991. It was found that, with certain limitations, the Surveyor (sn 1372) is capable of correlation with other roughness testing equipment and of providing test results meeting the requirements ofHPMS Class II equipment. Among the major limitations are the following: (1) on coarse-textured surfaces, the device is highly sensitive to variations in testing speed, and (2) the device is highly sensitive to changes in ambient temperature. The author concludes that these limitations are too severe for the device to be used in any except very uncritical roughness testing.
McGhee, K. H. (1992). Evaluation of a K.J. Law model 8300 ultrasonic roughness testing device (Report No. FHWA/VA-93R3). Virginia Transportation Research Council (VTRC). https://rosap.ntl.bts.gov/view/dot/19325
McGhee, Kenneth H. Evaluation of a K.J. Law model 8300 ultrasonic roughness testing device. Report no. FHWA/VA-93R3. Virginia Transportation Research Council (VTRC), 1992. https://rosap.ntl.bts.gov/view/dot/19325.
McGhee, Kenneth H Evaluation of a K.J. Law model 8300 ultrasonic roughness testing device. Virginia Transportation Research Council (VTRC), 1992, Report no. FHWA/VA-93R3, ROSA P. https://rosap.ntl.bts.gov/view/dot/19325.
ROSA P serves as an archival repository of USDOT-published products including scientific
findings, journal articles, guidelines, recommendations, or other information authored or co-authored by
USDOT or funded partners. As a repository, ROSA P retains documents in their original published format to
ensure public access to scientific information.
Links with this icon indicate that you are leaving a Bureau of Transportation
Statistics (BTS)/National Transportation Library (NTL)
Web-based service.
Thank you for visiting.
You are about to access a non-government link outside of
the U.S. Department of Transportation's National
Transportation Library.
Please note: While links to Web sites outside of DOT are
offered for your convenience, when you exit DOT Web sites,
Federal privacy policy and Section 508 of the Rehabilitation
Act (accessibility requirements) no longer apply. In
addition, DOT does not attest to the accuracy, relevance,
timeliness or completeness of information provided by linked
sites. Linking to a Web site does not constitute an
endorsement by DOT of the sponsors of the site or the
products presented on the site. For more information, please
view DOT's Web site linking policy.
To get back to the page you were previously viewing, click
your Cancel button.