Plaxico, C. A., Kennedy, J. C., & Miele, C. R. (2006). Development of an NCHRP report 350 TL-3 New Jersey shape 50-inch portable concrete barrier : final report, June 2006 (Report No. FHWA/OH-2006/16). Battelle Memorial Institute. https://rosap.ntl.bts.gov/view/dot/17534
Plaxico, Chuck A., James C. Kennedy, and Charles R. Miele. Development of an NCHRP report 350 TL-3 New Jersey shape 50-inch portable concrete barrier : final report, June 2006. Report no. FHWA/OH-2006/16. Battelle Memorial Institute, 2006. https://rosap.ntl.bts.gov/view/dot/17534.
Plaxico, Chuck A., et al. Development of an NCHRP report 350 TL-3 New Jersey shape 50-inch portable concrete barrier : final report, June 2006. Battelle Memorial Institute, 2006, Report no. FHWA/OH-2006/16, ROSA P. https://rosap.ntl.bts.gov/view/dot/17534.
For roadside work-zones in areas that have opposing traffic flow, safety is enhanced if the temporary barriers incorporate a "glare-shield" that blocks headlight glare from opposing traffic. Currently-available 32-inch portable concrete barriers require the use of an add-on glare shield attached to the top of the barrier. The add-on glare shields are an extra expense and complicate barrier set-up and handling. An alternative solution was to develop a 50-inch high portable concrete barrier which is tall enough to serve as its own glare-shield. Finite element analysis was used to investigate various barrier shapes and connection schemes to identify a successful crashworthy design that would meet requirments of NCHRP Report 350 Test level 3. A 50-inch portable concrete barrier design was developed based on the results of the finite element analyses and was crash tested at the Transportation Research Center in East Liberty, Ohio. The system successfully met all safety criteria of NCHRP Report 350 and has been approved by the Federal Highway Administration for use on the National Highway System as a test level 3 device.
Plaxico, C. A., Kennedy, J. C., & Miele, C. R. (2006). Development of an NCHRP report 350 TL-3 New Jersey shape 50-inch portable concrete barrier : final report, June 2006 (Report No. FHWA/OH-2006/16). Battelle Memorial Institute. https://rosap.ntl.bts.gov/view/dot/17534
Plaxico, Chuck A., James C. Kennedy, and Charles R. Miele. Development of an NCHRP report 350 TL-3 New Jersey shape 50-inch portable concrete barrier : final report, June 2006. Report no. FHWA/OH-2006/16. Battelle Memorial Institute, 2006. https://rosap.ntl.bts.gov/view/dot/17534.
Plaxico, Chuck A., et al. Development of an NCHRP report 350 TL-3 New Jersey shape 50-inch portable concrete barrier : final report, June 2006. Battelle Memorial Institute, 2006, Report no. FHWA/OH-2006/16, ROSA P. https://rosap.ntl.bts.gov/view/dot/17534.
ROSA P serves as an archival repository of USDOT-published products including scientific
findings, journal articles, guidelines, recommendations, or other information authored or co-authored by
USDOT or funded partners. As a repository, ROSA P retains documents in their original published format to
ensure public access to scientific information.
Links with this icon indicate that you are leaving a Bureau of Transportation
Statistics (BTS)/National Transportation Library (NTL)
Web-based service.
Thank you for visiting.
You are about to access a non-government link outside of
the U.S. Department of Transportation's National
Transportation Library.
Please note: While links to Web sites outside of DOT are
offered for your convenience, when you exit DOT Web sites,
Federal privacy policy and Section 508 of the Rehabilitation
Act (accessibility requirements) no longer apply. In
addition, DOT does not attest to the accuracy, relevance,
timeliness or completeness of information provided by linked
sites. Linking to a Web site does not constitute an
endorsement by DOT of the sponsors of the site or the
products presented on the site. For more information, please
view DOT's Web site linking policy.
To get back to the page you were previously viewing, click
your Cancel button.