Stormwater management practices (closed drainage) study (C-01-74) : laboratory simulation and field studies
-
2007-12-01
Details:
-
Creators:
-
Corporate Creators:
-
Subject/TRT Terms:
-
Resource Type:
-
Corporate Publisher:
-
Abstract:Two Stormwater Treatment Systems were instrumented and monitored in the field for one
year to evaluate their effectiveness at contaminant removal. The Vortechs® and the V2b1TM
were both installed by the NYS Department of Transportation at locations in Long Island,
NY and instrumented for this field study. They were evaluated by comparison of the inflow
and the outflow concentrations, in order to determine their removal efficiency for six
parameters: TSS/VSS, TPH, TKN, TP, BOD5 and FCB. Samples were collected at each
site during five storm events and lab analyses were performed at the Polytechnic University
laboratory, in Brooklyn, NY, following the Standard Method and EPA Procedures. Also,
the costs for installation and maintenance were studied.
-
Format:
-
Funding:
-
Collection(s):
-
Main Document Checksum:
-
Download URL:
-
File Type: