Full-Scale Controlled Tests of Wind Loads on Traffic Signal Structures
-
2008-05-01
Details
-
Creators:
-
Corporate Creators:
-
Corporate Contributors:
-
Subject/TRT Terms:
-
Publication/ Report Number:
-
Resource Type:
-
Geographical Coverage:
-
Edition:August 2003-October 2007
-
Corporate Publisher:
-
Abstract:The wind-induced vibrations of the mast arm of cantilever traffic signal structures can lead to the fatigue failure of these structures. For this project, both full-scale and wind tunnel tests were conducted to study the behavior of the structures. Results of these experiments indicated that when the signals have backplates, vortex shedding can cause large-amplitude vibrations that may lead to fatigue failure. These results contradict what has been generally accepted by other researchers: that galloping is the main cause for the fatigue inducing vibrations and that vortex shedding is of no relevance in this type of structure.
-