Distribution of Loads in Beam and Slab Bridge Floors
Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.

Search our Collections & Repository

All these words:

For very narrow results

This exact word or phrase:

When looking for a specific result

Any of these words:

Best used for discovery & interchangable words

None of these words:

Recommended to be used in conjunction with other fields

Language:

Dates

Publication Date Range:

to

Document Data

Title:

Document Type:

Library

Collection:

Series:

People

Author:

Help
Clear All

Query Builder

Query box

Help
Clear All

For additional assistance using the Custom Query please check out our Help Page

i

Distribution of Loads in Beam and Slab Bridge Floors

Filetype[PDF-2.66 MB]


  • English

  • Details:

    • Resource Type:
    • Geographical Coverage:
    • Abstract:
      Bridge Floors Currently most states use the American Association of State Highway Officials (AASHO) specifications for design of slab and beam floor systems. Since the present AASHO specifications (1957) show considerable error in the load distribution to the beams of some bridges, a number of methods have been developed by various individuals in order to obtain a closer correlation between design and test results. Some of these methods are discussed briefly in the Review of Literature section. In the present investigation another method is presented in which the distribution is solved in formula form for individual loadings instead of truck loadings. The solutions of the equations for the formulas are quite tedious but can be easily programmed and solved by a computer, thus eliminating the main disadvantage in solutions of this type. The theoretical results of this method were compared to tests using single loads on two laboratory test bridges and also with tests from two full-sized highway simple span bridges and two four span continuous highway bridges. The theory and test results are in close agreement; and as the use of electronic computers becomes more widespread in the highway field, this method will most likely take on more significance for the practical designer. In addition to the load distribution analysis, some work was also conducted in connection with deflections and shearing forces in the slab. The effective width of slab in connection with slab design was also studied.
    • Format:
    • Main Document Checksum:
    • File Type:

    Supporting Files

    • No Additional Files

    More +

    You May Also Like

    Checkout today's featured content at rosap.ntl.bts.gov

    Version 3.26