Ahlskog, C. (2018). Report on Techniques for Bridge Strengthening. Design Example – Stringer Retrofit - Composite Action and Continuity Changes (Report No. FHWA-HIF-18-044). United States. Department of Transportation. Federal Highway Administration. Office of Infrastructure. https://rosap.ntl.bts.gov/view/dot/42821
Ahlskog, C.. Report on Techniques for Bridge Strengthening. Design Example – Stringer Retrofit - Composite Action and Continuity Changes. Report no. FHWA-HIF-18-044. United States. Department of Transportation. Federal Highway Administration. Office of Infrastructure, 2018. https://rosap.ntl.bts.gov/view/dot/42821.
Ahlskog, C. Report on Techniques for Bridge Strengthening. Design Example – Stringer Retrofit - Composite Action and Continuity Changes. United States. Department of Transportation. Federal Highway Administration. Office of Infrastructure, 2018, Report no. FHWA-HIF-18-044, ROSA P. https://rosap.ntl.bts.gov/view/dot/42821.
This example involves the replacement of stringers during re-decking on an existing truss/floorbeam/stringer bridge. The existing stringers are non-composite rolled W24x76 beams, that were designed for HS-20 live loads. The design criteria is to provide new stringers to obtain a HS-25 live load rating factor equal to or greater than 1.0, while minimizing the weight of the new stringers. The flexural live load ratings of the new stringers were significantly increased by both making the stringers composite with the new deck and changing the continuity of the stringer spans. This example only involves a study of the flexural resistance of a typical interior span for the new and existing stringers using the Strength-I Limit State. This example is based on AASHTO LRFD Bridge Design Specifications, 7th Edition.
Ahlskog, C. (2018). Report on Techniques for Bridge Strengthening. Design Example – Stringer Retrofit - Composite Action and Continuity Changes (Report No. FHWA-HIF-18-044). United States. Department of Transportation. Federal Highway Administration. Office of Infrastructure. https://rosap.ntl.bts.gov/view/dot/42821
Ahlskog, C.. Report on Techniques for Bridge Strengthening. Design Example – Stringer Retrofit - Composite Action and Continuity Changes. Report no. FHWA-HIF-18-044. United States. Department of Transportation. Federal Highway Administration. Office of Infrastructure, 2018. https://rosap.ntl.bts.gov/view/dot/42821.
Ahlskog, C. Report on Techniques for Bridge Strengthening. Design Example – Stringer Retrofit - Composite Action and Continuity Changes. United States. Department of Transportation. Federal Highway Administration. Office of Infrastructure, 2018, Report no. FHWA-HIF-18-044, ROSA P. https://rosap.ntl.bts.gov/view/dot/42821.
ROSA P serves as an archival repository of USDOT-published products including scientific
findings, journal articles, guidelines, recommendations, or other information authored or co-authored by
USDOT or funded partners. As a repository, ROSA P retains documents in their original published format to
ensure public access to scientific information.
Links with this icon indicate that you are leaving a Bureau of Transportation
Statistics (BTS)/National Transportation Library (NTL)
Web-based service.
Thank you for visiting.
You are about to access a non-government link outside of
the U.S. Department of Transportation's National
Transportation Library.
Please note: While links to Web sites outside of DOT are
offered for your convenience, when you exit DOT Web sites,
Federal privacy policy and Section 508 of the Rehabilitation
Act (accessibility requirements) no longer apply. In
addition, DOT does not attest to the accuracy, relevance,
timeliness or completeness of information provided by linked
sites. Linking to a Web site does not constitute an
endorsement by DOT of the sponsors of the site or the
products presented on the site. For more information, please
view DOT's Web site linking policy.
To get back to the page you were previously viewing, click
your Cancel button.