Evaluation of Strand Transfer and Development Lengths in Pretensioned Girders With Semi-Lightweight Concrete
Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.

Search our Collections & Repository

For very narrow results

When looking for a specific result

Best used for discovery & interchangable words

Recommended to be used in conjunction with other fields

Dates

to

Document Data
Library
People
Clear All
Clear All

For additional assistance using the Custom Query please check out our Help Page

i

Evaluation of Strand Transfer and Development Lengths in Pretensioned Girders With Semi-Lightweight Concrete

Filetype[PDF-11.01 MB]


Select the Download button to view the document
This document is over 5mb in size and cannot be previewed
English

Details:

  • Creators:
  • Corporate Creators:
  • Corporate Contributors:
  • Subject/TRT Terms:
  • Publication/ Report Number:
  • Resource Type:
  • Geographical Coverage:
  • TRIS Online Accession Number:
    00771233
  • Edition:
    Final Report
  • Corporate Publisher:
  • Abstract:
    Indiana has been using lightweight aggregate consisting mostly of expanded shale in the production of prestressed concrete bridge girders for several projects. The lightweight aggregate has been used as partial replacement for regular gravel or crushed limestone coarse aggregate. This semi-lightweight concrete weighs around 2080 kg/cu m. In a study sponsored by the FHWA, the current AASHTO equations for the calculation of transfer and development lengths of prestressing strand were found to be unconservative in the case of lightweight concrete members with unit weight less than 1920 kg/cu m. This finding raises a question regarding the applicability of the same equations to semi-lightweight concrete members. The objective of this study is to determine if the current AASHTO specifications are applicable to semi-lightweight pretensioned concrete bridge members. The study addresses the transfer and development lengths of 13.3 mm and 15.2 mm pretensioned strand in semi-lightweight concrete girders with concrete compressive strength of 48 MPa for the 13.3 mm strand and 69 MPa for the 15.2 mm strand. Two strand types were considered in this study. The results of the laboratory evaluation suggest that the current transfer length of 50 strand diameters is adequate for semi-lightweight concrete if longitudinal cracks are not present along the transfer length. In the presence of longitudinal splitting cracks, the measured transfer length increased to approximately 70 strand diameters. It is recommended that the current requirements for strand development length be enforced at a distance "d sub p" from the point of maximum moment towards the free end of the strand. The quantity "d sub p" is the distance from the extreme compression fiber to the centroid of the prestressing steel but not less than 80% of the overall member height. In the specimens tested, web-shear cracks, intercepting the transfer length near the member ends, were not present.
  • Format:
  • Funding:
  • Collection(s):
  • Main Document Checksum:
  • Download URL:
  • File Type:

Supporting Files

  • No Additional Files
More +

You May Also Like

Checkout today's featured content at rosap.ntl.bts.gov