Development of recommended resistance factors for drilled shafts in weak rocks based on o-cell tests.
-
2010-03-01
Details:
-
Creators:
-
Corporate Creators:
-
Subject/TRT Terms:
-
Publication/ Report Number:
-
Resource Type:
-
Geographical Coverage:
-
Corporate Publisher:
-
Abstract:From October 1, 2007, the new bridges on federal-aid funded projects are mandated to be designed to meet
American Association of State Highway and Transportation Officials (AASHTO) Load and Resistance Factor Design
(LRFD) Bridge Design Specifications. LRFD is a simplified form of reliability-based design. By multiplying calibrated
factors to load and resistance components, the designed structure will maintain a specific level of reliability (or
probability of failure). By concept, the load and resistance factors should be calibrated by large number of test data;
however, they are often unavailable in geotechnical engineering. Significant efforts are needed to calibrate load and
resistance factors based on test data of good quality. In this study, 26 O-Cell test data were collected from Kansas,
Colorado, Missouri, Ohio, and Illinois. Seven methods available in the literature were selected to estimate the load
capacities of 25 out of 26 drilled shafts. The “FHWA 0.05D” method was found to yield the closest and conservative
predictions of the nominal resistances to the representative values; therefore, it was adopted in this study when
calibrating the resistance factors for Strength Limit State design. These test data were analyzed and used to calibrate
side and base resistance factors for drilled shafts in weak rock.
Resistance factors were calibrated at two different target reliability indices: 2.3 (i.e., failure probability, Pf≈1/100)
for shafts with greater redundancy and 3.0 (Pf ≈ 1/1000) for shafts with less redundancy. Side resistance factors were
calibrated from two different datasets of measured resistance: total side resistance and layered unit side resistance.
The resistance factors calibrated from layered unit side resistance are considered more reliable, therefore, they are
recommended for design. The recommended resistance factors from this study are compared with those in AASHTO
specifications. Some of those calibrated resistance factors from this study are considerably lower than those in
AASHTO specifications. The main reasons for such lower resistance factors are mainly attributed to the low efficiency
of the FHWA design method and the limited quality and number of O-Cell test data. These resistance factors may
be improved by increasing the size and the quality of the test data in the future. At present, field load tests on drilled
shafts are recommended as an alternative to using lower resistance factors, which will also accumulate more test
data for future improvement.
-
Format:
-
Funding:
-
Collection(s):
-
Main Document Checksum:
-
Download URL:
-
File Type: