Development of recommended resistance factors for drilled shafts in weak rocks based on o-cell tests.
-
2010-03-01
Details
-
Creators:
-
Corporate Creators:
-
Subject/TRT Terms:
-
Publication/ Report Number:
-
Resource Type:
-
Geographical Coverage:
-
Corporate Publisher:
-
Abstract:From October 1, 2007, the new bridges on federal-aid funded projects are mandated to be designed to meet ; American Association of State Highway and Transportation Officials (AASHTO) Load and Resistance Factor Design ; (LRFD) Bridge Design Specifications. LRFD is a simplified form of reliability-based design. By multiplying calibrated ; factors to load and resistance components, the designed structure will maintain a specific level of reliability (or ; probability of failure). By concept, the load and resistance factors should be calibrated by large number of test data; ; however, they are often unavailable in geotechnical engineering. Significant efforts are needed to calibrate load and ; resistance factors based on test data of good quality. In this study, 26 O-Cell test data were collected from Kansas, ; Colorado, Missouri, Ohio, and Illinois. Seven methods available in the literature were selected to estimate the load ; capacities of 25 out of 26 drilled shafts. The “FHWA 0.05D” method was found to yield the closest and conservative ; predictions of the nominal resistances to the representative values; therefore, it was adopted in this study when ; calibrating the resistance factors for Strength Limit State design. These test data were analyzed and used to calibrate ; side and base resistance factors for drilled shafts in weak rock. ; Resistance factors were calibrated at two different target reliability indices: 2.3 (i.e., failure probability, Pf≈1/100) ; for shafts with greater redundancy and 3.0 (Pf ≈ 1/1000) for shafts with less redundancy. Side resistance factors were ; calibrated from two different datasets of measured resistance: total side resistance and layered unit side resistance. ; The resistance factors calibrated from layered unit side resistance are considered more reliable, therefore, they are ; recommended for design. The recommended resistance factors from this study are compared with those in AASHTO ; specifications. Some of those calibrated resistance factors from this study are considerably lower than those in ; AASHTO specifications. The main reasons for such lower resistance factors are mainly attributed to the low efficiency ; of the FHWA design method and the limited quality and number of O-Cell test data. These resistance factors may ; be improved by increasing the size and the quality of the test data in the future. At present, field load tests on drilled ; shafts are recommended as an alternative to using lower resistance factors, which will also accumulate more test ; data for future improvement.
-
Format:
-
Funding:
-
Download URL:
-
File Type:
-
Collection(s):
-
Main Document Checksum:urn:sha256:3073f78a8f56f12d555981063929ac64335310161063df79885ac43d980561ad