Development of laboratory test methods to replace the simulated high-temperature grout fluidity test.

File Language:
English


Details

  • Creators:
  • Corporate Creators:
  • Corporate Contributors:
  • Subject/TRT Terms:
  • Publication/ Report Number:
  • Resource Type:
  • Geographical Coverage:
  • Corporate Publisher:
  • Abstract:
    This report contains a summary of the research performed to develop a replacement for the high-temperature grout ; fluidity (HTGF) test. The HTGF test was employed in the past by FDOT to qualify post-tensioning (PT) grouts for use in ; post-tensioned bridge construction. The HTGF test, however, is expensive and cumbersome to conduct in a typical ; construction materials testing laboratory. ; The objective of this research project was to develop a replacement for the HTGF test using a dynamic shear rheometer ; (DSR). Initially, exploratory studies were conducted using a number of DSR test methods and geometries to develop or ; adopt a method that provides more consistent and rational rheological results than the currently used flow cone test method. ; These studies led to the adoption of the viscosity test with a cup and ribbon geometry. The shear rate used in the viscosity ; test (50 s-1) was based on data from the literature and from the estimated shear rate at the nozzle of a flow cone. ; In addition to the DSR test development, HTGF tests were conducted twice on four different commercially available PT ; grouts. PT grout temperatures increased an average of 7°F (4°C) over the course of the circulation during HTGF testing. ; Line pressures measured at the pump during circulation ranged from 100 to 350 psi (4 kPa to 17 kPa). ; Viscosity results measured during the HTGF test were correlated to performance of the PT grouts. The viscosity results ; compared well with flow cone results with an R2 value of 0.85. From these data, performance classifications were ; developed based on the results of the testing. ; Finally, DSR testing was conducted at University of Minnesota-Duluth (UMD) and National Institute of Standards and ; Technology (NIST) to provide a comparison of the viscosity results from these laboratories to those produced by the ; University of Florida. Trends in viscosity test results compared well with results from both UMD and NIST. Absolute ; magnitudes, however, varied somewhat. This is thought to be due to the sensitive nature of the mixing and conditioning ; process. Additional performance classifications were developed based on the findings of these studies.
  • Format:
    PDF
  • Download URL:
  • File Type:
    Filetype[PDF - 2.38 MB]
  • Collection(s):
  • Main Document Checksum:
    urn:sha256:2acea86b2cb69d608eb43e5674094b986def65137cf9c84750279bc49abad525
File Language:
English
ON THIS PAGE
 Found an issue?
Send us an email at:
ROSA P serves as an archival repository of USDOT-published products including scientific findings, journal articles, guidelines, recommendations, or other information authored or co-authored by USDOT or funded partners. As a repository, ROSA P retains documents in their original published format to ensure public access to scientific information.