U.S. flag An official website of the United States government.
Official websites use .gov

A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS

A lock ( ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

i

Performance and capacity assessment of reinforced concrete bridge piers considering the current load and resistance factor design provisions and plastic hinge length in Kansas.

File Language:
English


Details

  • Creators:
  • Corporate Creators:
  • Subject/TRT Terms:
  • Publication/ Report Number:
  • Resource Type:
  • Geographical Coverage:
  • Corporate Publisher:
  • Abstract:
    Kansas Department of Transportation (KDOT) has implemented the new AASHTO-LRFD provisions in the state specific ; LRFD design procedure (KDOT LRFD). Most of the existing bridges constructed before the new provisions, have been designed ; based on the old provisions. In this study, these changes have been assessed based on the latest pertinent research, and two ; representative bridges, representing state bridges designed and constructed based on the new and old code versions have been ; studied and their performance were analyzed considering their real performance and new code revisions. ; In general, the two representative bridges provided by KDOT for this study, can safely address the demanded loads ; considering their actual strength and bridge structural-redundancy and load redistribution process. So, there is no immediate ; concern in terms of serviceability or collapse of these bridges under demanded loads, including the extreme vehicular impact load. ; However, the calculated shear strength of most of the columns designed and constructed based on the old codes may not be enough ; considering the new vehicular impact load required by the new code revisions. ; While no immediate action seems to be necessary in terms of serviceability and safety of these bridges, engineering ; judgment and a realistic case-based performance assessment is needed to decide if enhancement of the shear strength and the ; amount of lateral reinforcement within the plastic hinge length is necessary. Proper methods to retrofit these types of columns as ; detailed in Chapter 4 can be used, once a decision is made for a case to implement the aforesaid enhancement. The case-based ; appropriate retrofitting method can be specified for each case considering the column geometry, service load, reinforcement details ; and material properties.
  • Format:
    PDF
  • Funding:
  • Download URL:
  • File Type:
    Filetype[PDF - 5.20 MB]
  • Collection(s):
  • Main Document Checksum:
    urn:sha256:ca196210fe88e37761c81c06361babc45e0d05e87c9b291466707f3a12758b76
File Language:
English
ON THIS PAGE
 Found an issue?
Send us an email at:
ROSA P serves as an archival repository of USDOT-published products including scientific findings, journal articles, guidelines, recommendations, or other information authored or co-authored by USDOT or funded partners. As a repository, ROSA P retains documents in their original published format to ensure public access to scientific information.