U.S. flag An official website of the United States government.
Official websites use .gov

A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS

A lock ( ) or https:// means you've safely connected to the .gov website. Share sensitive information only on official, secure websites.

i

Evaluation of Effects of Fire on the I-465 Mainline Bridges : Volume II

File Language:
English


Select the Download button to view the document
Please click the download button to view the document.

Details

  • Alternative Title:
    JTRP Technical Reports
  • Creators:
  • Corporate Creators:
  • Corporate Contributors:
  • Subject/TRT Terms:
  • Publication/ Report Number:
  • Resource Type:
  • Geographical Coverage:
  • Edition:
    Final report.
  • Corporate Publisher:
  • Abstract:
    Currently, when a bridge has been involved in a fire loading, DOT and inspectors are called to determine if the bridge is passable to

    traffic. Inspectors must close the bridge for an indefinite period of time to take material samples from the bridge and have them tested

    to find if the strength of the materials meets AASHTO specifications. This procedure can take time and severely impact the economy of

    surrounding municipalities due to bridge closure. When a bridge is visually distorted, the recommendations of what must be done to

    repair the bridge may be intuitive; but when no apparent deformations are visible, a way of inspecting the bridge should be uniform and

    easily performed. The implementation of the findings of this report and the included inspection guide will provide inspectors a general

    idea of the changes in material properties of the bridge steel, based on the visual appearance of the steel.

    A method of testing has been developed that allows researchers to take flange and web sections from a bridge girder and test them in

    real fire scenarios. The test setup allows researchers to examine the differences in outcomes due to a variety of paint coatings on the

    steel, thickness of steel, temperature and duration of fire exposure. After each different test, material properties may be determined

    and compared to virgin or unexposed steel and AASHTO specifications to see if the material properties have changed or if the material is

    below minimum standards. Each specific test is photographed at certain stages that would be seen at a bridge in the field after being

    involved in a fire. These photographs can then be compared to actual bridge damage and an estimate of surface temperature could be

    attained. The inspection guide would then give average values for the reduction or increase of tensile strength and toughness for a

    particular bridge.

  • Format:
  • Funding:
  • Collection(s):
  • Main Document Checksum:
    urn:sha-512:404b815807de21ee94a49e0a2834d098dfbd13f1726890f2621d4fe529cd06c795fe4b0a8564e37b262be537e2a728ecde1ea85c960ad56d5af75755898c7654
  • Download URL:
  • File Type:
    Filetype[PDF - 73.03 MB ]
File Language:
English
ON THIS PAGE

ROSA P serves as an archival repository of USDOT-published products including scientific findings, journal articles, guidelines, recommendations, or other information authored or co-authored by USDOT or funded partners. As a repository, ROSA P retains documents in their original published format to ensure public access to scientific information.