Evaluation of reclaimed asphalt pavement for surface mixtures.
-
2012-03-01
Details
-
Creators:
-
Corporate Creators:
-
Corporate Contributors:
-
Subject/TRT Terms:
-
Publication/ Report Number:
-
Resource Type:
-
Geographical Coverage:
-
Edition:Final report.
-
Corporate Publisher:
-
Abstract:The Indiana Department of Transportation has successfully used Reclaimed Asphalt Pavement (RAP) for decades because of its economic ; and environmental benefits. Because of uncertainties regarding the types of aggregates contained in RAP and their resulting frictional ; properties, however, INDOT has until recently disallowed the use of RAP in asphalt surface mixtures. In addition, the hardened asphalt ; binder in the RAP could potentially increase the occurrence of thermal cracking. This research was conducted to explore the effects on ; RAP with poor or unknown aggregate qualities to establish maximum allowable RAP contents to provide adequate friction. The effects ; of RAP on thermal cracking were then investigated at the potential allowable RAP contents. ; Laboratory testing showed that the addition of poor quality RAP materials did impact the frictional properties and cracking resistance of ; the mixtures, but that lower amounts of RAP had little effect. The frictional performance of the laboratory fabricated and field sampled ; RAP materials was acceptable at contents of 25% but may be questionable at 40%. ; Field friction testing was also conducted on existing roadways with RAP to explore their field frictional performance. Several low volume ; roadways and one experimental interstate project were tested. The field results showed acceptable performance after 3 to 5 years of ; low volume traffic at RAP contents of 15‐25% and after more than 10 years of interstate traffic with 15% RAP. ; The low temperature testing showed an increased susceptibility to thermal cracking as the RAP content increased but the change in ; critical cracking temperature was relatively small at the 25% RAP level. At 40% RAP without a change in the virgin binder grade, the ; critical cracking temperature was about 6°C warmer than the control mixture. This finding supports the need for a binder grade change ; for RAP contents greater than 25%, as indicated in other research and as required by the current INDOT specifications.
-
Format:
-
Funding:
-
Download URL:
-
File Type:
-
Collection(s):
-
Main Document Checksum:urn:sha256:9fae53b091f86935d0bbd793f6fb3d4fcc5fe6194ce90405f9ef6510da5ad192