An evaluation of bituminized fiber pipe culverts.
Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.

Search our Collections & Repository

For very narrow results

When looking for a specific result

Best used for discovery & interchangable words

Recommended to be used in conjunction with other fields

Dates

to

Document Data
Library
People
Clear All
Clear All

For additional assistance using the Custom Query please check out our Help Page

i

An evaluation of bituminized fiber pipe culverts.

Filetype[PDF-1.08 MB]


English

Details:

  • Alternative Title:
    Culvert studies
  • Creators:
  • Corporate Creators:
  • Subject/TRT Terms:
  • Publication/ Report Number:
  • Resource Type:
  • Geographical Coverage:
  • Corporate Publisher:
  • Abstract:
    This report describes the results to date in a limited study, including laboratory tests and field evaluations, of the suitability of bituminized fiber pipe for use as highway culverts. Crushing strength data obtained from three-edge bearing tests indicate that bituminized fiber culverts, as currently produced, are not as strong as, and should not be considered an alternate to, plain concrete pipe. A need exists for a strength specification for bituminized fiber pipe in practical culvert diameters. Bituminized fiber pipe offers relative ease of handling and installation in comparison to concrete and steel culverts of equivalent diameter, but the observance of proper installation practices is apparently critical. The field test installations have served adequately under moderate loading conditions for periods as long as seven years, including five years' exposure to highly acidic runoff. Assuming the use of proper installation techniques, it appears that bituminized fiber pipe might be suitable for use in many locations having non-abrasive flow conditions on low traffic volume, rural secondary routes. Accordingly, it is recommended that bituminized fiber pipe culverts be considered for judicious use in the secondary road system, particularly in cases where acidic runoff is encountered. Such action will increase the experience of the Department of Highways with bituminized fiber culverts and allow the state to avail itself of any advantages the product may offer.
  • Format:
  • Collection(s):
  • Main Document Checksum:
  • Download URL:
  • File Type:

Supporting Files

  • No Additional Files
More +

You May Also Like

Checkout today's featured content at rosap.ntl.bts.gov