Field instrumentation and measured response of the I-295 cable-stayed bridge.
Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.

Search our Collections & Repository

All these words:

For very narrow results

This exact word or phrase:

When looking for a specific result

Any of these words:

Best used for discovery & interchangable words

None of these words:

Recommended to be used in conjunction with other fields

Language:

Dates

Publication Date Range:

to

Document Data

Title:

Document Type:

Library

Collection:

Series:

People

Author:

Help
Clear All

Query Builder

Query box

Help
Clear All

For additional assistance using the Custom Query please check out our Help Page

i

Field instrumentation and measured response of the I-295 cable-stayed bridge.

Filetype[PDF-3.53 MB]


  • English

  • Details:

    • Resource Type:
    • Geographical Coverage:
    • Edition:
      Final report.
    • Abstract:
      This first report describes the results of a field study of the live load responses of a segmentally constructed prestressed concrete cable-stayed bridge. The main span of the test structure consists of twin box girders connected by delta frames. Known vehicular loadings were placed statically at various points along the bridge. Strains measured during this loading were compared with those obtained from a finite element model of the bridge. Strain trends predicted by the finite element model were in good agreement with the measured strain trends. Quantitative agreement was fair, at least in part because of the high stiffness of the bridge and the limitations on the magnitude of load that could be applied. The second report describes the results of a field study of the thermal responses of a cable-stayed bridge. Data were gathered from the I-295 James River Bridge, a precast segmental concrete bridge with a cable-stayed main span consisting of twin box girders connected by delta frames. The thermal gradient and associated thermal strains in the box girders and pylons were measured using an extensive array of thermocouples and strain-gaged reinforcing bars installed at selected locations in the main-span box girder and south pylon. The temperature and strain response data were compared with that predicted from detailed finite element models of the structure using both frame and plate elements. Comparison revealed a complex three-dimensional strain pattern dependent on the wind direction and the angle of solar incidence. Simplified beam element models were unable to predict many of the observed local variations in thermal strain, which are influenced by wind direction, solar heating direction, proximity to the web, and the existence of parapets monolithic with the deck. Three-dimensional finite element models appear to be more capable of predicting the kind of three-dimensional strains observed, but quantitative agreement with the observed thermal strains was limited at best.
    • Format:
    • Main Document Checksum:
    • File Type:

    Supporting Files

    • No Additional Files

    More +

    You May Also Like

    Checkout today's featured content at rosap.ntl.bts.gov