Field instrumentation and measured response of the I-295 cable-stayed bridge.
Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.

Search our Collections & Repository

For very narrow results

When looking for a specific result

Best used for discovery & interchangable words

Recommended to be used in conjunction with other fields

Dates

to

Document Data
Library
People
Clear All
Clear All

For additional assistance using the Custom Query please check out our Help Page

i

Field instrumentation and measured response of the I-295 cable-stayed bridge.

Filetype[PDF-3.53 MB]


English

Details:

  • Creators:
  • Corporate Creators:
  • Subject/TRT Terms:
  • Publication/ Report Number:
  • Resource Type:
  • Geographical Coverage:
  • Edition:
    Final report.
  • Corporate Publisher:
  • Abstract:
    This first report describes the results of a field study of the live load responses of a segmentally constructed prestressed concrete cable-stayed bridge. The main span of the test structure consists of twin box girders connected by delta frames. Known vehicular loadings were placed statically at various points along the bridge. Strains measured during this loading were compared with those obtained from a finite element model of the bridge. Strain trends predicted by the finite element model were in good agreement with the measured strain trends. Quantitative agreement was fair, at least in part because of the high stiffness of the bridge and the limitations on the magnitude of load that could be applied. The second report describes the results of a field study of the thermal responses of a cable-stayed bridge. Data were gathered from the I-295 James River Bridge, a precast segmental concrete bridge with a cable-stayed main span consisting of twin box girders connected by delta frames. The thermal gradient and associated thermal strains in the box girders and pylons were measured using an extensive array of thermocouples and strain-gaged reinforcing bars installed at selected locations in the main-span box girder and south pylon. The temperature and strain response data were compared with that predicted from detailed finite element models of the structure using both frame and plate elements. Comparison revealed a complex three-dimensional strain pattern dependent on the wind direction and the angle of solar incidence. Simplified beam element models were unable to predict many of the observed local variations in thermal strain, which are influenced by wind direction, solar heating direction, proximity to the web, and the existence of parapets monolithic with the deck. Three-dimensional finite element models appear to be more capable of predicting the kind of three-dimensional strains observed, but quantitative agreement with the observed thermal strains was limited at best.
  • Format:
  • Collection(s):
  • Main Document Checksum:
  • Download URL:
  • File Type:

Supporting Files

  • No Additional Files
More +

You May Also Like

Checkout today's featured content at rosap.ntl.bts.gov