Corrosion protection performance evaluation of low permeable concretes in exposure specimens.
Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.

Search our Collections & Repository

All these words:

For very narrow results

This exact word or phrase:

When looking for a specific result

Any of these words:

Best used for discovery & interchangable words

None of these words:

Recommended to be used in conjunction with other fields

Language:

Dates

Publication Date Range:

to

Document Data

Title:

Document Type:

Library

Collection:

Series:

People

Author:

Help
Clear All

Query Builder

Query box

Help
Clear All

For additional assistance using the Custom Query please check out our Help Page

i

Corrosion protection performance evaluation of low permeable concretes in exposure specimens.

Filetype[PDF-3.09 MB]


  • English

  • Details:

    • Publication/ Report Number:
    • Resource Type:
    • Geographical Coverage:
    • TRIS Online Accession Number:
      762995
    • OCLC Number:
      40859946
    • Edition:
      Final contract report
    • NTL Classification:
      NTL-HIGHWAY/ROAD TRANSPORTATION-Bridges and Structures;NTL-HIGHWAY/ROAD TRANSPORTATION-HIGHWAY/ROAD TRANSPORTATION;NTL-HIGHWAY/ROAD TRANSPORTATION-Materials;
    • Abstract:
      The application of a mineral admixture or a combination of a mineral admixture with corrosion inhibitor are the methods used for the corrosion protection for reinforced concrete bridges. The results of a 1.5-year study on evaluation of three concretes with fly ash, slag cement (SC), and silica fume (SF) and one concrete with silica fume and a corrosion inhibitor (SFD) are presented. The specimens were built to simulate four exposure conditions typical for concrete bridges located in the coastal region or inland where deicing salts are used. The exposure conditions were horizontal, vertical, tidal, and immersed zones. The specimens were kept inside the laboratory and were exposed to weekly ponding cycles of 6% sodium chloride solution by weight. In addition, cover depth measurements from 21 bridge decks and chloride data from 3 bridge decks were used, together with laboratory data, in modeling the service lives of investigated corrosion protection methods. The methods used to assess the condition of the specimens included chloride concentration measurements, corrosion potentials, and corrosion rates (3LP). Additionally, visual observations were performed for identification of rust stains and cracking on concrete surfaces. The results of chloride testing indicate that the amount of chlorides present at the bar level is more than sufficient to initiate corrosion. Chloride and rapid permeability data demonstrate that for low permeable (LP) concretes there appears to be significant difference both in a rate of chloride ingress and in the diffusion coefficients in comparison to the controls. Corrosion potentials agree with corrosion rates and suggest the possibility of an active corrosion process development on control specimens during indoor exposure. The structural cracks that were observed in some specimens appeared to have no influence on the corrosion development on the bars in the vicinity of the these cracks. It was concluded that the silicone and duct tape protection was adequate. The cracking, other than structural, appeared to be related to the reinforcing steel corrosion, except the cracks in the horizontal zone of the specimen with slag cement which were probably caused by the subsidence cracking. The least number of cracks was observed on the SF and SFD specimens. Modeling the time as a function of probability of the end of functional service life (EFSL) was presented. It has been shown that the distributions of surface concentrations of chloride ions (CO) and diffusion constants (DC) are key elements in the model. Model predictions show that the LP concretes provide much better level of protection against moisture and chlorides than the A4 concrete alone. Application of a corrosion inhibitor causes an elevation of the chloride threshold resulting in an additional increase in time to EFSL. Recommendations are to continue monitoring until cracking has occurred in all specimens to a greater extent to better estimate the service lives of LP concretes than is presently known in the construction of concrete bridge components in Virginia. The specimens with LP concretes and one control (continuous reinforcement in the legs) should be taken to the Hampton Road North Tunnel Island and placed in the brackish water to a depth of the immersed zone at low tide for further exposure to chloride. The other control (non-continuous reinforcement in the legs) should remain in an outdoor exposure in Southwest Virginia like the Civil Engineering Materials Research Laboratory in Blacksburg, Virginia. Also more field studies are needed to better estimate distributions of surface chloride concentration and diffusion coefficient of Virginia bridge decks, and to confirm predicted times to EFSL for LP concretes.
    • Format:
    • Main Document Checksum:
    • File Type:

    Supporting Files

    • No Additional Files

    More +

    You May Also Like

    Checkout today's featured content at rosap.ntl.bts.gov

    Version 3.26