Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.

Search our Collections & Repository

All these words:

For very narrow results

This exact word or phrase:

When looking for a specific result

Any of these words:

Best used for discovery & interchangable words

None of these words:

Recommended to be used in conjunction with other fields

Language:

Dates

Publication Date Range:

to

Document Data

Title:

Document Type:

Library

Collection:

Series:

People

Author:

Help
Clear All

Query Builder

Query box

Help
Clear All

For additional assistance using the Custom Query please check out our Help Page

i

Post-Tensioning the Inverted-T Bridge System for Improved Durability and Increased Span-To-Depth Ratio

Filetype[PDF-3.44 MB]


  • English

  • Details:

    • Corporate Creators:
    • Corporate Contributors:
    • Publication/ Report Number:
    • Resource Type:
    • Geographical Coverage:
    • TRIS Online Accession Number:
      1080622
    • Abstract:
      Possibly the most pressing need in highway construction today is the repair or replacement of existing bridges. Due to increased needs and growing traffic, in addition to aging and extensive use, more than 2000 bridges in Kansas alone need to be replaced during the next decade. The majority of these bridges have spans of 100 ft or less, and have relatively shallow profiles. It is becoming increasingly important to implement a standard method for replacement in which the process is expedited and accomplished in a cost-effective manner. Requirements for design and construction of concrete bridges have drastically changed during recent years. A main change in design is live-load requirements. The Nebraska inverted-T (IT) bridge system has gained increasing popularity for its lower weight compared to I-girder bridges. However, there are some limiting issues when using IT system in replacing existing cast-in-place (CIP) bridges. Implementation of a post-tensioned IT (PT-IT) system, which is the focus of this project, is believed to be one excellent solution for the IT deficiencies. Post-tensioning is added by placing a draped, post-tensioning duct in the stems of the IT members. Post-tensioning will lead to a higher span-to-depth ratio than IT system, and will reduce the potential transverse cracks in the CIP deck. Finally, the undesired cambers of pretensioned beams will be reduced, because fewer initial pre-stressing will be needed. This study was intended to explore the behavior of the a PT-IT system, identify major parameters that control and limit the design of this system, and investigate different construction scenarios. This was achieved by conducting an extensive parametric study. For that purpose, PT-IT analysis program was developed and written using C++ programming language. The program was used to analyze various post-tensioning procedures for the post-tensioned inverted-T system. A Visual Basic friendly interface was provided to simplify the data input process. The findings of this project included recommendation of construction scenario for PT-IT system, as well as examining different methods for estimating time-dependent restraining moments. The effect of different concrete strengths on the behavior of the PT-IT system was also determined. Most importantly, the effect of timing on different construction stages was also evaluated and determined.
    • Format:
    • Funding:
    • Main Document Checksum:
    • File Type:

    Supporting Files

    • No Additional Files

    More +

    You May Also Like

    Checkout today's featured content at rosap.ntl.bts.gov

    Version 3.26