Performance of strip seals in Iowa bridges, pilot study.

Filetype[PDF-4.56 MB]


  • English

  • Details:

    • Corporate Creators:
    • Publication/ Report Number:
    • Resource Type:
    • Geographical Coverage:
    • Edition:
      Final report.
    • Corporate Publisher:
    • Abstract:
      A pilot study was conducted on the premature failures of neoprene strip seals in

      expansion joints in Iowa bridges. In a relatively large number of bridges, strip seals have

      pulled out of the steel extrusions or otherwise failed well before the expected life span of the

      seal. The most serious consequence of a strip-seal failure is damage to the bridge

      substructure due to salt, water, and debris interacting with the substructure.

      A literature review was performed. Manufacturers’ specifications and

      recommendations, practices in the states bordering Iowa, and Iowa DOT design and

      installation guidelines were reviewed. Discussions were held with bridge contractors and the

      installation of a strip seal system was observed. Iowa DOT bridge databases were analyzed.

      A national survey was conducted on the use and performance of strip seals.

      With guidance from the Iowa DOT, twelve in-service bridges with strip-seal

      expansion joints were selected for detailed investigation. Effective bridge temperatures and

      corresponding expansion-joint openings were measured, DOT inspection reports were

      reviewed, and likely cause(s) of premature failures of strip seals were proposed.

      All of the seals used in the twelve bridges that had the most serious failures were in

      concrete girder bridges. Experimental results show that for a majority of these serious

      failures, the joint opening at 0° F predicted by the Iowa DOT design equations, the joint

      opening at 0° F extrapolated from the experimental data, or both, are larger than the

      movement rating of the strip seal specified on the bridge plans. Other likely causes of

      premature failures of seals in the twelve bridges include debris and ice in the seal cavity, a

      large skew and the corresponding decrease in the movement rating of the seal, improper

      installation, and improper setting of the initial gap.