Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.

Search our Collections & Repository

All these words:

For very narrow results

This exact word or phrase:

When looking for a specific result

Any of these words:

Best used for discovery & interchangable words

None of these words:

Recommended to be used in conjunction with other fields

Language:

Dates

Publication Date Range:

to

Document Data

Title:

Document Type:

Library

Collection:

Series:

People

Author:

Help
Clear All

Query Builder

Query box

Help
Clear All

For additional assistance using the Custom Query please check out our Help Page

i

Development and layout of a protocol for the field performance of concrete deck and crack sealers.

Filetype[PDF-2.28 MB]


  • English

  • Details:

    • Alternative Title:
      Title from technical report page: Development and layout of a protocol for the field performance of concrete deck and crack sealers
    • Publication/ Report Number:
    • Resource Type:
    • Geographical Coverage:
    • Edition:
      Final report; Nov. 2006-Sept. 2009.
    • Abstract:
      The main objective of this project was to develop and layout a protocol for the long-term monitoring and assessment of the performance of concrete deck and crack sealants in the field. To accomplish this goal, a total of six bridge decks were chosen for study. The decks have ages that vary from 4 to 30 years old, are all in good condition, though some presented a variety of longitudinal, transverse and diagonal cracking. In each deck, test segments were laid out along one lane in four of the six bridges. Drill powder samples were extracted in each segment in order to determine the in-situ, near-surface chloride ion content of the deck. Laboratory analyses of the samples showed that the chloride ion content varied between 3.2 lb/cy for the younger decks (3 years old) and 20.8 lb/cy for the older decks (28 years old). Based on the recommendations of a previous laboratory investigation, a pool of the best performing deck and crack sealants were selected to be applied in the decks. In two bridges, deck segments were sealed with four deck sealants while one segment was left unsealed to be used as a control segment. Additionally, the cracks in each of these segments were sealed with five crack sealants. While two other decks were also scheduled for sealing as part of this phase of the project, they were not done because the required curing time for some of the products was longer than deemed acceptable by DOT crews for these high traffic bridges. It is recommended, however, that every effort be made to have these decks be sealed in the near future. The remaining two bridges had been sealed at the time of construction. While no specific information could be secured about the product used in these decks, the low chloride ion content in these decks suggested that the applied product has helped reduce the ingress of chloride ions. Therefore, it is recommended that these decks continue to be monitored over time. Based on the inspections and the data collected in the field, a protocol and schedule for the continuing monitoring of sealant performance is presented.
    • Format:
    • Main Document Checksum:
    • File Type:

    Supporting Files

    • No Additional Files

    More +

    You May Also Like

    Checkout today's featured content at rosap.ntl.bts.gov

    Version 3.26