Abdomen Impact Testing of the THOR-50M Anthropomorphic Test Device
-
2021-02-01
Details:
-
Creators:
-
Corporate Creators:
-
Corporate Contributors:
-
Subject/TRT Terms:
-
Publication/ Report Number:
-
Resource Type:
-
Geographical Coverage:
-
Edition:02/27/20 to 05/19/20
-
Contracting Officer:
-
Corporate Publisher:
-
Abstract:FRA sponsors ongoing research on passenger rail equipment occupant protection at the Volpe Center. The Volpe Center contracted Calspan to conduct pendulum impact testing of the THOR-50M ATD. A series of 28 pendulum impact tests was performed on the lower chest and abdomen of the THOR-50M to evaluate: (1) biofidelity, (2) height sensitivity, (3) velocity sensitivity, and (4) repeatability. The test results indicate that the THOR-50M had a similar level of abdomen biofidelity to other advanced frontal impact ATDs. The THOR-50M was sensitive to variations in impact height and speed, and the tests were generally repeatable. The results will be used to inform potential updates to the abdomen compression performance limit for the THOR-50M in the industry safety standard for crashworthy workstation tables in passenger trains.
-
Format:
-
Funding:
-
Collection(s):
-
Main Document Checksum:
-
Download URL:
-
File Type: